The Diagnostic Utility of Multiphase-CT (4D CT) in Localising Parathyroid Adenomas Following Negative or Discordant 99mTc-Sestamibi SPECT/CT and Ultrasound Imaging.
Jake E Cowen, Xavier Fung, Matthew Ward, Hani Nasef, Darryl Meeking, David N Poller, Jasper Bekker
Department of Radiology, Queen Alexandra Hospital, Portsmouth Hospitals University NHS Trust, United Kingdom, PO6 3LY. · Department of Ear, Nose & Throat Surgery, Queen Alexandra Hospital, Portsmouth Hospitals University NHS Trust, United Kingdom, PO6 3LY.
Key points
From the paper's conclusion- Multiphase CT provided reliable diagnostic accuracy for localisation and lateralisation of parathyroid adenomas in the context of discordant or negative first-line imaging. Its high specificity and moderate positive likelihood ratios make it a valuable rule-in tool that enables targeted surgical approaches.
Abstract
OBJECTIVES: To quantify the diagnostic utility of multiphase-CT as a second line imaging modality for parathyroid adenoma localisation including assessing the differences between patients undergoing second line imaging due to negative or discordant first-line imaging (MIBI SPECT/CT) results. METHODS: Patients undergoing multiphase-CT following negative or discordant first-line imaging were collected retrospectively over a 5-year period from 2019-2023. 73 patients were included. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, positive and negative likelihood ratios of multiphase CT for preoperative parathyroid adenoma lateralisation (correct side) and localisation (correct quadrant) were calculated. Results for the whole cohort, negative imaging cohort and discordant imaging cohorts were compared. RESULTS: Fifty-eight of the included patients were female, and 15 were male. Mean age was 56.2 ± 11.8. One-hundred and eighty-three quadrants and 98 sides were explored surgically. 69.8% patients underwent a minimally invasive surgical procedure. Across the whole cohort, multiphase CT demonstrated a sensitivity of 70.4% (95% CI 58-81) and specificity of 86.4% (79-92). For lateralisation, performance was higher with sensitivity 82.6% (72-91) and specificity 86.2% (68-96). Moderate positive likelihood ratios were also recorded as 5.26 (localisation) and 5.99 (lateralisation). CONCLUSIONS: Multiphase CT provided reliable diagnostic accuracy for localisation and lateralisation of parathyroid adenomas in the context of discordant or negative first-line imaging. Its high specificity and moderate positive likelihood ratios make it a valuable rule-in tool that enables targeted surgical approaches. ADVANCES IN KNOWLEDGE: This study provides one of the largest datasets in the literature. Positive results suggest that CT can be considered in cases of negative or discordant first-line imaging if minimally invasive surgical techniques are desired.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging.Insights into imaging · 2026
- Photon-Counting Detector 4D CT for Preoperative Localization in Primary Hyperparathyroidism.AJNR. American journal of neuroradiology · 2026
- Dual-phase planar scintigraphy and early versus delayed SPECT/CT in [99mTc]Tc-MIBI imaging for primary hyperparathyroidism: a blinded comparative study.Endokrynologia Polska · 2026
- Incremental Value of Multimodality Imaging for Preoperative Localization in Primary Hyperparathyroidism: A Stepwise Strategy for Focused Parathyroidectomy.Turkish archives of otorhinolaryngology · 2026
- Dual-isotope subtraction scintigraphy and SPECT-CT for preoperative localization of parathyroid adenomas.Clinical physiology and functional imaging · 2026
- Diagnostic performance of 3T MRI preoperative localization of parathyroid adenomas in primary hyperparathyroidism.Frontiers in endocrinology · 2026