European radiology

Photon-counting detector CT for gastric cancer T staging: a comparative assessment with conventional energy integrating detector CT.

Changfeng Ji, Lin Li, Yuqing Li, Yiju Zhou, Wan Yang, Shuangshuang Sun, Kehui Nie, Xi Zhao,

Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China. · Department of Pathology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.

Observational · n=54

Key points

From the paper's conclusion
  • PCD-CT demonstrated significantly higher quantitative image quality metrics (SNR and CNR) and numerically higher diagnostic performance than EID-CT in this exploratory retrospective comparison. The potential value of PCD-CT in gastric cancer T staging warrants further validation.

Abstract

OBJECTIVE: This study aimed to evaluate the diagnostic performance of photon-counting detector computed tomography (PCD-CT) for gastric cancer T staging compared with conventional energy-integrating detector CT (EID-CT). MATERIALS AND METHODS: Fifty-three patients with preoperative PCD-CT and 54 patients with preoperative EID-CT were retrospectively enrolled. Two radiologists independently assessed the visibility and T stages using all available sequences, including virtual monoenergetic images (VMIs) from PCD-CT at 40, 50, 60, and 70 kiloelectron volt (keV) levels. The lesion detectability and diagnostic accuracy of the two CT systems were analyzed and compared. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of gastric cancer lesions were also measured. RESULTS: Five lesions in the PCD-CT group and 12 lesions in the EID-CT group could not be confidently identified. For visible lesions, the overall T staging accuracies were 85.4% (95% CI: 72.8-92.8%) for Reader 1 and 83.3% (95% CI: 70.4-91.3%) for Reader 2 on PCD-CT, compared with 73.8% (95% CI: 58.9-84.7%) for Reader 1 and 78.6% (95% CI: 64.1-88.3%) for Reader 2 on EID-CT. The interobserver agreement for both CT systems was excellent, with weighted kappa values of 0.807 (95% CI: 0.693-0.921) for PCD-CT and 0.832 (95% CI: 0.720-0.943) for EID-CT. Quantitative analysis showed significantly higher SNR and CNR on PCD-CT than EID-CT (both p < 0.05). CONCLUSION: PCD-CT demonstrated significantly higher quantitative image quality metrics (SNR and CNR) and numerically higher diagnostic performance than EID-CT in this exploratory retrospective comparison. The potential value of PCD-CT in gastric cancer T staging warrants further validation. KEY POINTS: Question The diagnostic performance and potential value of PCD-CT in gastric cancer T staging are still unclear. Findings PCD-CT showed significantly higher quantitative image quality metrics (SNR and CNR) and numerically higher diagnostic performance than EID-CT in this exploratory comparison. Clinical relevance PCD-CT may offer potential value in gastric cancer T staging.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Photon-counting detector CT for gastric cancer T staging: a comparative assessment with conventional energy integrating detector CT — Science Skim