Surgical and radiologic anatomy : SRA

Assessment of masseter and temporalis muscle properties in healthy young adults using shear wave elastography and MyotonPRO.

Aslıhan Artaş, Firdevs Aşantoğrol, Zübeyde Uçar Gündoğar, Zeynep Şencan, Ceyda Şevval Çetin, Rümeysa İnce, Orhan Beger, Ömer Faruk Cihan,

Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Gaziantep University, Gaziantep, Türkiye. · Department of Pediatric Dentistry, Faculty of Dentistry, Gaziantep University, Gaziantep, Türkiye.

Observational

Key points

From the paper's conclusion
  • Although standardized z-score comparisons showed no significant group-level differences between SWE and MPRO, the absence of significant correlations at rest and the presence of a significant but weak correlation only for the masseter during contraction after Holm correction indicate limited individual-level correspondence between the two methods. These findings suggest that SWE and MPRO may provide complementary rather than directly interchangeable information on masticatory muscle properties.

Abstract

OBJECTIVES: To examine the relationship between stiffness measurements obtained using shear wave elastography (SWE) and MyotonPRO (MPRO) within the same muscle and functional state, and to establish sample-specific baseline values for the masseter and temporalis muscles in healthy young adults aged 19-29 years under standardized resting and contraction conditions. METHODS: In this cross-sectional study, 100 healthy young adults aged 19-29 years were included. For analytical consistency, MPRO stiffness values were abbreviated as MR-S, MC-S, TR-S, and TC-S, representing the masseter at rest, masseter during contraction, temporalis at rest, and temporalis during contraction, respectively; the corresponding SWE measurements were denoted as MR-SWE, MC-SWE, TR-SWE, and TC-SWE. Holm correction was applied across the 120 correlation tests to account for multiple testing. RESULTS: No significant correlation was found between SWE- and MPRO-derived stiffness values for the masseter or temporalis muscles under resting conditions (MR-S vs. MR-SWE, Holm-adjusted p = 1.000, r = 0.065; TR-S vs. TR-SWE, Holm-adjusted p = 1.000, r = -0.100). During contraction, a weak positive correlation was observed for the masseter muscle (MC-S vs. MC-SWE, Holm-adjusted p = 0.012, r = 0.268), whereas the very weak correlation for the temporalis muscle was no longer statistically significant after correction (TC-S vs. TC-SWE, Holm-adjusted p = 1.000, r = 0.141). Standardized comparison using z-scores showed no significant differences between the two methods for either muscle at rest or during contraction (MR, p = 0.872; TR, p = 0.607; MC, p = 0.608; TC, p = 0.697). CONCLUSIONS: Although standardized z-score comparisons showed no significant group-level differences between SWE and MPRO, the absence of significant correlations at rest and the presence of a significant but weak correlation only for the masseter during contraction after Holm correction indicate limited individual-level correspondence between the two methods. These findings suggest that SWE and MPRO may provide complementary rather than directly interchangeable information on masticatory muscle properties.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers