Cortical button versus suture anchor fixation in distal biceps tendon repair: a comparison of objective four-plane strength and functional outcomes.
Yaiza Lopiz, Javier Guijarro, Pablo Checa, Carlos García-Fernández, Fernando Marco
Surgery Department, Universidad Complutense de Madrid, Madrid, Spain. mlopiz@ucm.es. · Hospital Clínico San Carlos, Madrid, Spain.
Key points
From the paper's conclusion- No significant strength differences were found between techniques, although the small sample cannot exclude clinically relevant differences and fixation was confounded with treatment era. A small supination and flexion deficit persisted after both techniques.
Abstract
PURPOSE: To compare four-plane isometric strength, function and complications between cortical button and suture anchor fixation in distal biceps repair, and to explore the influence of surgical delay. METHODS: Twenty-eight men (mean age, 44.2 years) underwent single-incision repair with a cortical button (n = 16) or suture anchors (n = 12) between 2020 and 2025. At a mean follow-up of 46 months, we assessed isometric strength in four planes with a hand-held dynamometer (relative to the uninjured side), range of motion, QuickDASH, Mayo Elbow Performance Score (MEPS), Oxford Elbow Score (OES) and complications. A sensitivity analysis included only patients followed for ≥ 24 months. RESULTS: Mean strength was 93.8% (flexion), 100.1% (extension), 90.3% (supination) and 97.2% (pronation; median, 94.2%); all planes except extension remained below the uninjured side (P ≤ 0.016). Strength did not differ between techniques in any plane, also in the sensitivity analysis. Functional scores were high in both groups, with small differences in favour of suture anchors that should be interpreted with caution (MEPS 100 vs. 95.0, P = 0.022; QuickDASH 1.3 vs. 5.5, P = 0.046; OES 47.4 vs. 43.4, P = 0.069). Repair after 21 days (n = 6; exploratory) was associated with weaker flexion (85.4% vs. 96.1%, P = 0.024). No reruptures occurred; three patients (10.7%) had transient neurapraxia. CONCLUSION: No significant strength differences were found between techniques, although the small sample cannot exclude clinically relevant differences and fixation was confounded with treatment era. A small supination and flexion deficit persisted after both techniques.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cortical Button and Suture Anchor Fixation for Distal Biceps Tendon Repair Provide Similar Clinical Outcomes and Complication Profiles: A Systematic Review.Journal of shoulder and elbow surgery · 2026
- A Retrospective Cohort Study of Distal Biceps Brachii Tendon Rupture and Subsequent Repair Methods: A Comparison of Two Combined Treatment Pathways.Cureus · 2026
- Knot-Dependent Constructs Show Narrowly Better Ultimate Failure Loads Than Knotless Constructs in Proximal Biceps Tenodesis: A Systematic Review and Meta-analysis.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- Double-Cinch and Modified Mason-Allen Meniscal Root Repairs Demonstrate Comparable Time-Zero Biomechanical Performance with Cortical Button or Knotless Anchor Fixation: A Controlled Porcine Study.Journal of ISAKOS : joint disorders & orthopaedic sports medicine · 2026
- Comparison of screw and suture-button techniques in the treatment of ankle syndesmotic injuries.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2026
- A modified transosseous quadriceps tendon refixation technique demonstrates advantageous primary stability: A biomechanical investigation.Journal of experimental orthopaedics · 2026