From the paper's conclusion- This study aimed to evaluate the accuracy of two imageless navigation systems for restoring leg length change (LLC) and global offset change (GOC) in total hip arthroplasty (THA) using two-dimensional (2D) radiographic and three-dimensional computed tomography (3D CT)-based assessment methods.
Abstract
PURPOSE: This study aimed to evaluate the accuracy of two imageless navigation systems for restoring leg length change (LLC) and global offset change (GOC) in total hip arthroplasty (THA) using two-dimensional (2D) radiographic and three-dimensional computed tomography (3D CT)-based assessment methods. METHODS: Patients undergoing primary cementless THA were divided into two groups based on the imageless navigation system used: a large-console group (n = 120) and a portable handheld group (n = 83). Intraoperative navigation measurements of the LLC and GOC were compared with values derived from preoperative and postoperative assessments, and absolute measurement errors were calculated. Accuracy was evaluated using 2D radiographic and 3D CT-based measurements. Between-system differences and discrepancies between 2 and 3D assessment methods were analyzed. RESULTS: Absolute LLC error in the large-console group was 2.7 ± 3.3 mm on 2D radiographic evaluation and 2.5 ± 3.3 mm on 3D CT-based evaluation, compared with 2.9 ± 2.7 mm and 3.0 ± 2.8 mm, respectively, in the portable handheld group. LLC error was significantly lower in the large-console group on 3D evaluation (p = 0.004). Absolute GOC error did not differ significantly between groups. No differences were observed between 2 and 3D evaluations for LLC, whereas most GOC-related parameters differed significantly between methods. CONCLUSION: Imageless navigation systems achieved favorable accuracy for LLC and GOC in THA. While radiographic assessment is sufficient for evaluating leg length, 3D CT-based evaluation provides a more consistent and less position-dependent assessment of global offset.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- FP12.7 Imageless Navigation in Hip Resurfacing Arthroplasty: Accuracy of Cup Positioning and Leg Length RestorationJournal of Hip Preservation Surgery · 2026
- A novel pinless augmented reality-based navigation system for total hip arthroplasty in the supine position: a comparative study of acetabular cup angle accuracyArchives of Orthopaedic and Trauma Surgery · 2026
- Accuracy of acetabular cup installation angles using two augmented reality navigation systems: computed tomography-based and noninvasive portable systems in total hip arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Robotic assistance in total hip arthroplasty: a systematic review and meta-analysis of leg length, cup orientation, and early outcomes.Journal of robotic surgery · 2026
- CT-based navigation for acetabular cup placement in supine and lateral positions: a simulated surgery study using patient-specific 3D-printed pelvic models.Frontiers in surgery · 2026
- Visually detectable pointer deviation of the nextar surgical navigation system with c-arm, o-arm and ct imaging: a bench-top study using a two-dimensional phantom.BMC musculoskeletal disorders · 2026