Five-compartment restriction spectrum imaging for noninvasive assessment of liver fibrosis in chronic liver disease.
Hui Chen, Songhua Zhan, Zhiwei Qin, Xiaojun Zhu, Chao Zheng, Huamei Yan, Weian Yuan, Jie Yuan
Department of Radiology, Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China. · MR Collaborative Innovation Department, Shanghai United Imaging Healthcare Co., Ltd., Shanghai, China.
Key points
From the paper's conclusion- Five-compartment RSI provides diffusion metrics associated with histologic fibrosis stage, and RSI-LF showed diagnostic performance numerically comparable to that of MRE. RSI is a promising microstructure-sensitive biomarker for liver fibrosis staging that warrants multicenter validation.
Abstract
BACKGROUND: Noninvasive staging of liver fibrosis is essential in chronic liver disease (CLD). Magnetic resonance elastography (MRE) is well validated but requires dedicated hardware, whereas the apparent diffusion coefficient (ADC) derived from conventional diffusion-weighted imaging (DWI) lacks specificity. Restriction spectrum imaging (RSI) decomposes the diffusion signal into multiple compartments and may capture fibrosis-related microstructural changes. PURPOSE: To investigate the feasibility of RSI for noninvasive liver fibrosis staging in CLD and to compare its diagnostic performance with that of MRE, using liver biopsy as the reference standard. METHODS: This retrospective study included 100 consecutive patients with CLD who underwent liver biopsy, 3.0-T multi-b-value DWI (nine b values, 0-1500 s/mm²), and MRE within 6 months. Multi-compartment RSI models (K = 2-5) were fitted to region-of-interest-averaged signals, and the optimal model was selected using the Bayesian information criterion (BIC). An RSI liver fibrosis index (RSI-LF) was derived from compartment fractions using ordinal logistic regression and internally validated with 1000 bootstrap resamples. AUCs of RSI-LF were compared with those of MRE and ADC using the paired DeLong test. RESULTS: The five-compartment RSI model (RSI5) showed the lowest BIC. The second and fourth fractions, K5C2 and K5C4, correlated positively (ρ = 0.53) and negatively (ρ = -0.55) with fibrosis stage (both false discovery rate [FDR]-adjusted p < 0.001). RSI-LF yielded AUCs of 0.774 (95% CI: 0.651-0.898), 0.863 (0.793-0.933), and 0.911 (0.842-0.981) for ≥F2, ≥F3, and F4, respectively, with negligible bootstrap optimism. AUCs did not differ significantly from those of MRE at any threshold (all p > 0.05). RSI-LF also outperformed ADC at the ≥F3 and F4 thresholds (both p < 0.001). CONCLUSION: Five-compartment RSI provides diffusion metrics associated with histologic fibrosis stage, and RSI-LF showed diagnostic performance numerically comparable to that of MRE. RSI is a promising microstructure-sensitive biomarker for liver fibrosis staging that warrants multicenter validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Restricted Spectrum Imaging for Diagnosis of High-Risk Metabolic Dysfunction-Associated Steatohepatitis.Journal of magnetic resonance imaging : JMRI · 2026
- Evaluation of magnetic resonance elastography performance in the assessment of clinically significant liver fibrosis in pediatric metabolic dysfunction-associated steatotic liver disease.Journal of pediatric gastroenterology and nutrition · 2026
- Virtual MR elastography with diffusion-weighted imaging to evaluate chronic kidney disease fibrosis and dysfunction.Radiology advances · 2026
- Superiority of magnetic resonance elastography and proton density fat fraction: an umbrella meta-analysis of non-invasive imaging for hepatic steatosis and fibrosis in metabolic dysfunction-associated steatotic liver disease and chronic hepatitis B.Quantitative imaging in medicine and surgery · 2026
- Native T1 mapping radiomics for assessing FIB-4-associated fibrosis risk in metabolic dysfunction-associated steatotic liver disease.Quantitative imaging in medicine and surgery · 2026
- Standardizing Liver MR Elastography: Guidelines for Reliable Stiffness Measurement in Chronic Liver Disease.Radiology · 2026