Virtual MR elastography with diffusion-weighted imaging to evaluate chronic kidney disease fibrosis and dysfunction.
Ruirui Qi, Junfeng Li, Wenxi Liu, Peiyin Luo, Qiuyi Chen, Qiumei Liang, Fanqi Meng, Jinhua Qin,
Department of Radiology, The Fourth Clinical Medical College of Guangzhou University of Chinese Medicine (Shenzhen Traditional Chinese Medicine Hospital), Shenzhen, Guangdong 518033, China. · Medical AI Lab, School of Biomedical Engineering, Medical School, Shenzhen University, Shenzhen, Guangdong 518055, China.
Key points
From the paper's conclusion- Diffusion-weighted imaging-derived µdiff enables vibration-free renal vMRE, offering a stiffness-related surrogate that correlates with renal dysfunction and fibrosis. Diagnostic performance is comparable to MRE, including in early-stage CKD. If validated externally, this may provide a scalable alternative for CKD evaluation.
Abstract
BACKGROUND: Renal stiffness declines with chronic kidney disease (CKD) progression. Magnetic resonance elastography (MRE) enables quantitative assessment of tissue stiffness but requires external hardware, limiting routine clinical use. PURPOSE: To develop a diffusion-derived virtual shear modulus (µdiff) for vibration-free renal virtual MR elastography (vMRE) and evaluate its ability to assess dysfunction and fibrosis across CKD stages. MATERIALS AND METHODS: This prospective single-center study included 53 healthy volunteers and 114 CKD patients, stratified by estimated glomerular filtration rate (eGFR) into early-stage CKD (CKD1-2, eGFR 60-120 mL/min/1.73 m2) and moderate-to-advanced CKD (CKD3-5, eGFR < 60 mL/min/1.73 m2). Renal biopsy results performed for clinical care were collected. Magnetic resonance elastography and multi-b-value diffusion-weighted imaging (DWI) (b = 0-2000 s/mm2) were performed on a 3T MRI (MAGNETOM Prisma, Siemens). Cortical shifted apparent diffusion coefficient (csADC) across b-value combinations correlated with cortical MR elastographic shear modulus (cµMRE) to identify the optimal combination and derive µdiff. Age-adjusted analysis of covariance (ANCOVA) compared MRI parameters. Partial correlations with eGFR and Spearman correlations with interstitial fibrosis (IF) were performed. Diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS: A significant correlation (R 2 = 0.94, P < .001) was observed between cµMRE and csADC derived from DWI at b-values of 200 (S200) and 800 (S800) s/mm2 (csADC200-800), yielding μ diff ( kPa ) = 4.91 ln ( S 200 / S 800 ) + 0.92 . Cortical µdiff (cμdiff) correlated with eGFR (r = 0.602, P < .001) and IF (r = -0.809, P < .001). In biopsied patients (n = 51), cμdiff showed comparable diagnostic performance to cµMRE in differentiating mild from moderate-to-severe IF (area under the curve [AUC], 0.910 [95% CI, 0.822-0.998] vs 0.901 [95% CI, 0.813-0.989]; P > .05). CONCLUSION: Diffusion-weighted imaging-derived µdiff enables vibration-free renal vMRE, offering a stiffness-related surrogate that correlates with renal dysfunction and fibrosis. Diagnostic performance is comparable to MRE, including in early-stage CKD. If validated externally, this may provide a scalable alternative for CKD evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Multiparametric MR Imaging for Detecting Early Chronic Kidney Disease and Grading Chronic Pathological ChangesJournal of Magnetic Resonance Imaging · 2026
- Research progress of virtual magnetic resonance elastography.Magnetic resonance imaging · 2026
- Finite Element Elastographic Analysis of Kidney MRI for Computational Assessment of Chronic Kidney DiseasearXiv · 2026
- Noninvasive assessment of renal allograft function with multiparametric MRI: DWI, DTI, and arterial spin labeling compared with eGFR.Magnetic resonance imaging · 2026
- Altered microstructure in end-stage renal disease patients with maintenance hemodialysis: A diffusion kurtosis imaging analysis.Medicine · 2026
- Assessment of Renal Cortical Stiffness in Diabetes Mellitus by Shear Wave Elastography Ultrasound.Journal of medical ultrasound · 2026