Programmed death ligand 1 (PD-L1) PET/CT imaging to evaluate tumour saturation during atezolizumab treatment.
Jahlisa S Hooiveld-Noeken, Pim P van de Donk, Laura Kist de Ruijter, Iris C Kok, Claudia A J van Winkel, Danique Giesen, Marjolijn N Lub-de Hooge, Adrienne H Brouwers,
Departments of Medical Oncology, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands. · Departments of Nuclear Medicine and Molecular Imaging, University Medical Centre Groningen, University of Groningen, Groningen, The Netherlands.
Key points
From the paper's conclusion- Compared to earlier reported pre-treatment 89Zr-atezolizumab PET/CT results, 89Zr-atezolizumab tumour uptake during treatment is lower, suggesting partial PD-L1 tumour saturation during atezolizumab treatment.
Abstract
BACKGROUND: Little is known regarding tumour target saturation by the programmed death-ligand (PD-L1) antibody atezolizumab. Therefore, tumour saturation by the PD-L1 antibody atezolizumab in patients with advanced solid tumours was assessed using 89Zr-atezolizumab PET imaging. METHODS: Patients received 10 mg 89Zr-atezolizumab after the initial 2 cycles of 1200 mg atezolizumab, followed by PET/CT scans. Tracer uptake was calculated as tumour standardized uptake value (SUV)max, normal tissues SUVmean, and tumour-to-background ratio SUVmax/SUVmax tumour. Tumour biopsies were obtained around day 7 of both cycles for autoradiography and PD-L1 immunohistochemistry. Findings were compared with previously reported pretreatment 89Zr-atezolizumab PET/CT data. RESULTS: Geometric mean tumour SUVmax day 7 was similar between cycle 1 (5.5, 95% CI, 4.4-6.9) and 2 (5.4, 95% CI, 4.3-6.8, N = 13, P = 0.88). Geometric mean tumour-to-background ratio was 1.67 (95% CI, 1.15-2.41) and 1.53 (N = 11, 95% CI, 1.05-2.21, P = 0.32), respectively. Higher tumour-to-background ratios showed a positive trend with best overall response ptrend 0.069. Autoradiography signal was present in tumour biopsies. On-treatment uptake was lower in the lesions and spleen, with a higher blood pool SUVmean than pre-treatment. CONCLUSIONS: Compared to earlier reported pre-treatment 89Zr-atezolizumab PET/CT results, 89Zr-atezolizumab tumour uptake during treatment is lower, suggesting partial PD-L1 tumour saturation during atezolizumab treatment. CLINICALTRIALS: GOV: NCT02453984, NCT02478099.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Modular Antibody-Based Platform for PD-L1 Pretargeted SPECT Imaging and In Vitro 177Lu Cytotoxicity in a Murine Melanoma Model.Molecules (Basel, Switzerland) · 2026
- Pharmacokinetics of Prostate Cancer Lesions on Dual Time-Point PET/CT: A Predictive Factor for Response to PSMA Radioligand Therapy?Nuklearmedizin. Nuclear medicine · 2026
- In-human assessment of target engagement and blockade of radiolabeled BI 765063, an anti-SIRPα antibody.EJNMMI research · 2026
- Preclinical evaluation of PD-L1 targeted radiotherapy in a xenograft mouse model of triple-negative breast cancerEJNMMI Research · 2026
- PD-L1 PET/CT imaging with 18F-BMS-986,229 and 18F-BMS-986,192 in patients with advanced-stage non-small cell lung cancer.European journal of nuclear medicine and molecular imaging · 2026
- 18F-BMS-986192 PET to Predict Durable Response to Nivolumab in NSCLC: A Novel Approach Beyond PD-L1 Immunohistochemistry.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026