First-in-human dosimetry and biodistribution of [89Zr]Zr-oxine-labeled autologous leukocytes using PET/CT.
Kadir Gultekin, Jennifer L Bartels, Carlos E Cardenas, Yogesh Kumar, Grayson R Gimblet, Chloe L Jones, Christina Bankston, Charlotte D Jeffers,
Department of Biomedical Engineering, University of Alabama at Birmingham, Birmingham, AL, 35294, USA. · Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, 35294, USA.
Key points
From the paper's conclusion- This study demonstrates the safety and favorable dosimetry of [89Zr]Zr-oxine-labeled leukocytes in healthy humans. These results support the further use of this approach for imaging autologous leukocytes using PET in a range of clinical and research settings.
Abstract
PURPOSE: Cell tracking with zirconium-89 PET has the potential for widespread clinical and research applications, including imaging infection and inflammation and tracking cell-based therapies. This prospective first-in-human clinical trial assessed the dosimetry and safety profile of [89Zr]Zr-oxine-labeled autologous leukocytes in healthy female participants. METHODS: Four healthy adult female participants (ages 37-53) received 10.9 ± 2.9 MBq of [89Zr]Zr-oxine-labeled autologous leukocytes and underwent whole-body PET/CT imaging at five time points (0, 4, 24, 48, and 72 h). Regions of interest were automatically segmented on CT using a machine learning-based approach and manually refined. Time-integrated activity coefficients were calculated using Simpson's rule, with physical decay assumed beyond the final time point. Mean absorbed-dose and effective-dose coefficients were estimated using OLINDA 2.1. RESULTS: Administration was well-tolerated among all participants. The highest mean absorbed-dose coefficients (mGy/MBq) with standard deviation were observed in the spleen (3.52 ± 1.38), liver (2.1 ± 0.45), adrenals (1.62 ± 0.24), uterus (1.48 ± 0.98), and kidneys (1.36 ± 0.12). The mean effective-dose coefficient was 0.92 ± 0.06 mSv/MBq, numerically lower than the predicted value of 1.14 mSv/MBq based on the distribution of [111In]In-oxine-labeled leukocytes in adult females (P = 0.006, one-sample t-test). The use of [89Zr]Zr-oxine-labeled leukocytes enabled the visualization of leukocyte distribution and temporal dynamics. CONCLUSION: This study demonstrates the safety and favorable dosimetry of [89Zr]Zr-oxine-labeled leukocytes in healthy humans. These results support the further use of this approach for imaging autologous leukocytes using PET in a range of clinical and research settings. TRIAL REGISTRATION: ClinicalTrials.gov NCT03807973. Registered January 16, 2019.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of [89Zr]Zr-oxine labelling and PET/CT imaging for tracking mesenchymal stem cells in mice and patients with perianal fistula.Stem cell research & therapy · 2026
- Preclinical Evaluation of 89Zr-Labeled Anti-Nectin-4 Antibody for Enhanced PET Imaging in Bladder Urothelial Carcinoma.Journal of medicinal chemistry · 2026
- Longitudinal PET Imaging Reveals the Biological Fate, Pharmacokinetics, and Clearance of Zirconium-89-Labeled MXene Nanosheets In Vivo.Nanotheranostics · 2026
- Radiation protection considerations following administration of zirconium-89 labeled tracers: are patient restrictions necessary?Nuclear medicine communications · 2026
- Clinical nuclear medicine applications of zirconium-89 immuno-PET: a comprehensive review from a radiopharmaceutical perspectiveEJNMMI Radiopharmacy and Chemistry · 2026
- Programmed death ligand 1 (PD-L1) PET/CT imaging to evaluate tumour saturation during atezolizumab treatment.British journal of cancer · 2026