Skeletal radiology

Performance of a self-supervised pretrained neural network for orthopedic radiograph classification.

Rohan Bagchi, Nicholas J Yee, John Y Kwon, Atta Taseh, Soheil Ashkani-Esfahani

Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA. rbagchi@mgh.harvard.edu. · Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA.

Computational · n=1,775

Key points

From the paper's conclusion
  • With no significant difference in AUROC from either baseline, domain-adapted self-supervised pretraining yielded more faithful attributions than supervised ImageNet pretraining in every experiment and than self-supervised ImageNet pretraining in two of three. No model generalized adequately to unfamiliar anatomy without fine-tuning. Groups fine-tuning on their own musculoskeletal data should therefore consider domain-adapted weights, whose saliency maps more reliably show what drove each prediction, making reliance on irrelevant features easier to detect.

Abstract

OBJECTIVE: To evaluate whether domain-adaptive self-supervised pretraining of a convolutional neural network on musculoskeletal radiographs improves binary fracture classification and attribution faithfulness relative to ImageNet-pretrained baselines. MATERIALS AND METHODS: This retrospective study (conducted June 2025 to May 2026) compared three initializations of a ResNet-50 convolutional neural network: supervised ImageNet (control), self-supervised ImageNet (DINO), and DINO further pretrained on 44,029 musculoskeletal radiographs (DINO-Ortho). Each was fine-tuned in three experiments: in-distribution (MURA and FracAtlas), out-of-distribution (5365 external calcaneal radiographs from 1775 patients acquired during 2015-2022), and initial weights (calcaneal fine-tuning). Attribution faithfulness was quantified using Remove and Debias (ROAD) scores from Grad-CAM saliency maps, with higher scores indicating greater faithfulness. AUROCs were compared using DeLong tests, and ROAD scores using Friedman tests with Bonferroni-adjusted post hoc pairwise comparisons. RESULTS: DINO-Ortho AUROC did not differ significantly from either baseline in any experiment (0.82 [95% confidence interval, 0.79-0.84] in-distribution and 0.95 [0.93-0.96] with initial weights). DINO-Ortho ROAD scores were significantly higher than both baselines in-distribution (20.01 vs 3.70 and 9.35, respectively) and with initial weights (20.41 vs 12.15 and 1.67, respectively, P < 0.001 for all) and higher than control but not DINO out-of-distribution (15.47 vs 3.06 and 16.09, respectively). All models discriminated poorly out-of-distribution (AUROC 0.65 [0.63-0.67], 0.64 [0.63-0.66], and 0.64 [0.63-0.66] for control, DINO, and DINO-Ortho, respectively). CONCLUSION: With no significant difference in AUROC from either baseline, domain-adapted self-supervised pretraining yielded more faithful attributions than supervised ImageNet pretraining in every experiment and than self-supervised ImageNet pretraining in two of three. No model generalized adequately to unfamiliar anatomy without fine-tuning. Groups fine-tuning on their own musculoskeletal data should therefore consider domain-adapted weights, whose saliency maps more reliably show what drove each prediction, making reliance on irrelevant features easier to detect.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers