An Explainable Deep Learning Framework for Musculoskeletal Abnormality Detection.
Saeed Ur Rehman, Muhammad Saad, Anwar Ali, Muhammad Awais
School of Computer Science, University of Hull, Hull HU6 7RX, UK. · Faculty of Science and Engineering, Swansea University, Swansea SA1 8EN, UK.
Key points
From the paper's conclusion- The findings demonstrate the feasibility of integrating transfer learning, Grad-CAM-based visual attribution, activation-based weak localization, and sensitivity-oriented decision-making within a unified framework for musculoskeletal abnormality classification.
Abstract
Accurate detection of musculoskeletal abnormalities from radiographs remains challenging because abnormal findings can be subtle and radiographic appearance may vary considerably across examinations. This study aimed to develop and systematically evaluate a deep learning framework incorporating Grad-CAM-based visual attribution for automated musculoskeletal abnormality detection using the publicly available Musculoskeletal Radiographs (MURA) dataset. Four transfer learning architectures, namely DenseNet201, EfficientNetV2-S, ConvNeXt Tiny, and Swin Transformer Tiny, were evaluated for musculoskeletal abnormality classification. The framework incorporated Grad-CAM-based attribution and activation-based weak localization to highlight image regions associated with model predictions without requiring bounding-box annotations during training and a sensitivity-oriented decision threshold to prioritize the detection of abnormal examinations. Model performance was assessed using recall, precision, F1-score, area under the receiver operating characteristic curve (AUC), and confusion matrix analysis. A targeted decision-threshold ablation analysis compared the sensitivity-focused threshold of 0.40 with the conventional 0.50 baseline using the same validation-set probabilities. Previously published results were reviewed to provide contextual information rather than establish comparative superiority. EfficientNetV2-S achieved the highest precision (0.925), F1-score (0.892), and AUC (0.956) on the internal validation set among the evaluated architectures. DenseNet201 achieved the highest recall of 0.876. Previously published performance metrics were reviewed to contextualize the results of the present study. However, differences in datasets, anatomical coverage, preprocessing procedures, and evaluation protocols preclude direct conclusions regarding comparative superiority. At the sensitivity-focused threshold of 0.40, EfficientNetV2-S obtained an accuracy of 0.896 and an F1-score of 0.892 on the internal validation set. Lowering the threshold to 0.40 improved sensitivity from 0.754 to 0.861 and decreased false-negative predictions from 1092 to 618 when compared to the traditional threshold of 0.50. Alongside this improvement, false-positive predictions increased from 150 to 307 and specificity decreased from 0.966 to 0.931. Grad-CAM visualizations and activation-derived bounding boxes provided qualitative information about spatial attribution. However, their correspondence with pathological findings was not independently validated using expert annotations or quantitative localization metrics. On the independent held-out test set, EfficientNetV2-S achieved a recall of 0.826, precision of 0.886, F1-score of 0.855, and AUC of 0.927. The independent evaluation demonstrated lower performance than the internal validation results, highlighting the importance of separating model optimization from final performance assessment. The findings demonstrate the feasibility of integrating transfer learning, Grad-CAM-based visual attribution, activation-based weak localization, and sensitivity-oriented decision-making within a unified framework for musculoskeletal abnormality classification. Although the framework demonstrated promising classification performance, the visual attribution results remain exploratory and do not establish pathological localization accuracy or clinical interpretability. Further evaluation using external clinical datasets, expert-annotated pathological regions, and radiologist assessment is required to establish its generalizability, explanation validity, and potential clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated classification of musculoskeletal abnormalities using a dynamic ensemble of deep vision models.Medical & biological engineering & computing · 2026
- Attention-Guided EfficientNet-B3 with Grad-CAM Visualization for 22-Class Bone Fracture and Anatomical-Region Classification on the MultiBoneX Dataset.Diagnostics (Basel, Switzerland) · 2026
- Comparative evaluation of explainable vision models for bone tumour detection on radiographs.Frontiers in digital health · 2026
- Medical image pretraining-based transfer learning for generalizable and robust diagnosis of bone tumors on radiographs: a multi-center studyInsights into Imaging · 2026
- Critical Validation of Deep Learning-Based Cervical Vertebral Fracture Detection on Computed Tomography Localizer Radiographs.Journal of imaging informatics in medicine · 2026
- Deep Learning for Proximal Femoral Fracture Radiographs Under Archive-Label Uncertainty: A Duplicate-Controlled Single-Center Study.Medical sciences (Basel, Switzerland) · 2026