Skeletal radiology

Diagnostic accuracy of 3D MRI rendering techniques for evaluation of hourglass-like constrictions in Parsonage-Turner syndrome.

Delaram Shakoor, Emma J McKinney, Sophie C Queler, Cecilia Davis-Hayes, Max Hao, Adam Baker, Shu-Han Wang, Ek T Tan,

Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70 St, New York, NY, 10021, USA. shakoord@hss.edu. · Department of Radiology and Imaging, Hospital for Special Surgery, 535 E 70 St, New York, NY, 10021, USA.

Observational

Key points

From the paper's conclusion
  • High inter-reader agreement and sensitivity but variable specificity for HGC detection suggest both techniques are viable tools for MRN, with cMPR better suited for detailed HGC evaluation and MIP for initial screening.

Abstract

OBJECTIVE: To evaluate inter-reader agreement and diagnostic accuracy of curved multiplanar reformatting (cMPR) and maximum intensity projection (MIP) techniques for detecting hourglass-like constrictions (HGCs). MATERIALS AND METHODS: Thirty brachial plexus 3-Tesla, 3D, 1-mm isotropic MR neurography (MRN) datasets (10 patients without and 20 patients with Parsonage-Turner syndrome (PTS) affecting the suprascapular nerve (SSN)) were retrospectively analyzed by four musculoskeletal radiology fellows for the number and severity of HGCs using both post-processing views in a randomized, blinded fashion. An experienced, attending radiologist served as the reference standard. Inter-reader agreement was assessed using Gwet's AC1 and intraclass correlation (ICC). Image interpretation time was compared using Wilcoxon signed-rank test. RESULTS: Inter-reader agreement for HGC presence was substantial to almost perfect among fellows (cMPR AC1 = 0.7, MIP AC1 = 0.67) and when compared to the attending (cMPR AC1 = 0.67-0.83, MIP AC1 = 0.63-0.83). Agreement for severe HGC count was substantial to almost perfect (fellows: cMPR ICC = 0.65, MIP ICC = 0.79; vs. attending: ICC = 0.62-0.83, MIP ICC = 0.69-0.88), but poor to fair for mild HGCs (fellows: cMPR ICC = 0.23, MIP ICC = 0.26; vs. attending: ICC = 0-0.21, MIP ICC = 0-0.09). Sensitivity to HGC presence was excellent (cMPR, 85-100%; MIP, 90-100%), though specificity (cMPR, 50-100%; MIP, 40-90%) and diagnostic accuracy (cMPR, 80-90%; MIP, 76-90%) varied. The MIP method required significantly less interpretation time than cMPR (median: 33 vs. 104 s, p < 0.001). CONCLUSION: High inter-reader agreement and sensitivity but variable specificity for HGC detection suggest both techniques are viable tools for MRN, with cMPR better suited for detailed HGC evaluation and MIP for initial screening.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers