Thrombocytopenia Following Transcatheter Self-Expanding Pulmonary Valve Replacement.
Yuval Barak-Corren, Eli Fried, Maali Abu Omer, Tamir Dagan, Gabriel Amir, Einat Birk, Elchanan Bruckheimer
Cardiac Catheterization Laboratory, Section of Pediatric Cardiology, Schneider Children's Medical Center of Israel, Kaplan 14, 42902, Petach Tikva, Israel. · Cardiac Catheterization Laboratory, Section of Pediatric Cardiology, Schneider Children's Medical Center of Israel, Kaplan 14, 42902, Petach Tikva, Israel. elchananb@bezeqint.net.
Key points
From the paper's conclusion- Thrombocytopenia following transcatheter aortic valve implantation has been described, but platelet count decline after self-expanding transcatheter pulmonary valve replacement (TPVR) has not been previously highlighted.
Abstract
Thrombocytopenia following transcatheter aortic valve implantation has been described, but platelet count decline after self-expanding transcatheter pulmonary valve replacement (TPVR) has not been previously highlighted. This study aimed to describe the frequency, magnitude, and short-term clinical associations of platelet count decline after self-expanding TPVR. We retrospectively reviewed all consecutive self-expanding TPVRs performed at our institution between May 2022 and August 2025. Demographic, procedural, echocardiographic, and laboratory data were collected, including platelet and hemoglobin levels before and after TPVR. Descriptive statistics were used, and correlation analysis assessed the relationship between platelet and hemoglobin decreases. Forty-one patients were included, with a median age of 18.7 years [IQR 16.1-23.9]; 80% had undergone tetralogy of Fallot repair. Twenty-one patients received a Harmony valve and 20 received an Alterra-Sapien valve. Pre- and post-procedural platelet counts were available in 30 patients. A platelet count decrease occurred in 27/30 patients (90%), including 23/30 (77%) with a decrease of > 25% or ≥ 50 × 10⁹/L. Platelet count fell below 150 × 10⁹/L in 14 patients (47%) and below 100 × 10⁹/L in five (17%). No bleeding or thrombotic complications were observed, and no patient required platelet transfusion or thrombocytopenia-directed intervention. Hemoglobin decrease was less common and did not correlate with platelet count decrease. No difference was observed between valve types. Early platelet count decline was frequent after self-expanding TPVR, with nearly half developing thrombocytopenia. Routine post-procedural platelet monitoring may be warranted.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical Significance of Midterm Platelet Count Reduction After Transcatheter Aortic Valve Replacement.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Peri-procedural immune blood cell count changes and pacemaker implantation after transcatheter aortic valve implantation: an exploratory study.Kardiochirurgia i torakochirurgia polska = Polish journal of cardio-thoracic surgery · 2026
- Does thrombocytopenia predict short-term mortality after transcatheter and surgical aortic valve replacement?Interdisciplinary cardiovascular and thoracic surgery · 2026
- Early Outcomes of Self-Expandable Versus Balloon-Expandable Valves for Managing Dysfunctional Right Ventricular Outflow TractsCirculation Cardiovascular Interventions · 2025
- Conduction Disturbances and Permanent Pacemaker Implantation After TAVR With Self-Expanding Devices: The CONNAVIPRO Study.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Multi-level thromboinflammatory activation after TAVR: systemic, cellular, and platelet transcriptomic changesEuropean Heart Journal · 2026