Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions

Clinical Significance of Midterm Platelet Count Reduction After Transcatheter Aortic Valve Replacement.

Motoyoshi Takahara, Kan Zen, Kensuke Kuwabara, Yoji Nagata, Daichi Hato, Kazuaki Takamatsu, Issei Ota, Ryo Shibata,

Department of Cardiovascular Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan. · Department of Cardiovascular Medicine, Kishiwada Tokushukai Hospital, Kishiwada, Japan.

Observational · n=837

Key points

From the paper's conclusion
  • Greater DPC at 6 months after TAVR was associated with subsequent all-cause mortality. Patients treated with balloon-expandable valves had greater DPC at 6 months than those treated with self-expandable valves. These findings suggest that mid-term platelet dynamics may provide useful information for risk assessment after TAVR.

Abstract

BACKGROUND: The prognostic significance of a mid-term decrease in platelet count (DPC) after transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to evaluate the association between 6-month DPC and subsequent mortality and compare platelet changes between valve types. AIMS: To investigate the prognostic significance of a mid-term decrease in DPC after TAVR. METHODS: This retrospective, multicenter observational study included 837 patients who underwent TAVR. Clinical outcomes were assessed from a 6-month landmark through 1 year after TAVR. Cox proportional hazards regression was performed to evaluate the association between DPC at 6 months and subsequent all-cause mortality. Propensity score matching was performed to compare changes in platelet count between valve types. RESULTS: Between the 6-month landmark and 1 year after TAVR, 33 patients (3.9%) died. The mean 6-month DPC was 12.2% ± 22.1%. Exploratory analyses using a data-derived cutoff showed higher all-cause mortality (11.7% vs. 2.4%) and cardiovascular mortality (9.5% vs. 1.0%) with DPC ≥ 31.65% than with DPC < 31.65% (both p < 0.001). Greater DPC remained associated with all-cause mortality after adjustment (HR 1.24 per 10-percentage-point increase; 95% CI, 1.05-1.48; p = 0.011). After propensity score matching, 6-month DPC was greater with balloon-expandable than with self-expandable valves (14.9% vs. 7.0%, p < 0.001). CONCLUSIONS: Greater DPC at 6 months after TAVR was associated with subsequent all-cause mortality. Patients treated with balloon-expandable valves had greater DPC at 6 months than those treated with self-expandable valves. These findings suggest that mid-term platelet dynamics may provide useful information for risk assessment after TAVR.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers