Urolithiasis

Hydrodynamic outcomes of suction-assisted retrograde intrarenal surgery under different irrigation, suction, and ureteroscope conditions: an ex vivo porcine study.

Tianfu Ding, Daxun Luo, Ruijian Liu, Zhongjie Shan, Bo Xiao, Jianxing Li

Department of Urology, Research Center for Urinary Disease, School of Clinical Medicine, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, 102218, China. · Department of Urology, Ordos Central Hospital, Ordos, 017000, Inner Mongolia, China.

Key points

From the paper's conclusion
  • To characterize hydrodynamic outcomes under different irrigation, suction, and ureteroscope conditions during suction-assisted retrograde intrarenal surgery (RIRS) in an ex vivo porcine model.Two single-use flexible ureteroscopes (6.3-Fr and 7.3-Fr, identical 3.6-Fr working channel, same manufacturer) were matched with a 10/12-Fr ureteral access sheath.

Abstract

To characterize hydrodynamic outcomes under different irrigation, suction, and ureteroscope conditions during suction-assisted retrograde intrarenal surgery (RIRS) in an ex vivo porcine model.Two single-use flexible ureteroscopes (6.3-Fr and 7.3-Fr, identical 3.6-Fr working channel, same manufacturer) were matched with a 10/12-Fr ureteral access sheath. Independent variables included two irrigation rates (100, 200 mL/min) and three suction levels (0, - 75 mmHg, - 150 mmHg). Primary endpoints covered stone fragment evacuation rate, mean intrarenal pressure (IRP), cumulative duration of IRP > 30 mmHg, depressurization time (RT1/RT2), and collecting-system collapse grade. Each experimental combination was repeated 10 times.Without suction, mean IRP ranged from 56.3 to 79.1 mmHg and the duration of IRP > 30 mmHg exceeded 42.4 s within the 60-s observation period. Both suction magnitudes maintained mean IRP below 30 mmHg and eliminated measurable high-pressure exposure. The highest fragment evacuation rate was achieved with the 6.3-Fr ureteroscope at 200 mL/min irrigation flow and - 150 mmHg suction (2.134 ± 0.896 g/min), exceeding the rate observed with the 7.3-Fr configuration (1.482 ± 0.346 g/min). Active suction accelerated pressure-relief kinetics relative to passive depressurization (RT2 < RT1). Mild collecting-system collapse (Grade 1) occurred exclusively under low inflow (100 mL/min) combined with active suction, indicating that collapse is driven by net fluid balance rather than absolute IRP alone.Within a 10/12-Fr ureteral access sheath, active suction effectively reduced IRP, eliminated high-pressure exposure above 30 mmHg during the 60-s observation period, and accelerated pressure relief. The 6.3-Fr ureteroscope demonstrated a more favourable pressure-clearance profile than the 7.3-Fr ureteroscope under the tested conditions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers