Worldwide variations in purchase and per-procedure costs of single-use flexible ureteroscopes and flexible navigable access sheaths: the economic impact of reuse strategies on procedural outcomes from a 40-country YAU-EAU endourology international collaboration.
Amelia Pietropaolo, Hayder Alhusseinawi, Boyke Soebhali, Johan Cabrera, Azimdjon Tursunkulov, Deepak Ragoori, Fabio C Vincentini, Gaston M Astroza,
Urology, University Hospital Southampton, Southampton, UK. ameliapietr@gmail.com. · Department of Urology, North Denmark Regional Hospital, Hjørring, Denmark.
Key points
From the paper's conclusion- These findings highlight the importance of considering regional cost structures and resource utilization when evaluating the value of emerging endourological technologies.
Abstract
Endourological practice increasingly relies on single-use devices, the costs of which vary considerably across regions and healthcare systems. Flexible single-use ureteroscopes (FURS) and flexible and navigable suction ureteral access sheaths (FANS) represent a substantial proportion of ureteroscopy-related expenditure. To mitigate these costs, some centres have adopted reuse strategies aimed at reducing per-procedure expenses. The aim of this study was to evaluate international variation in the purchase prices and real-world per-procedure costs of FURS and FANS, and to assess the economic impact of device reuse strategies. An international collaborative study coordinated by the Young Academic Urologists (YAU) and European Association of Urology (EAU) Endourology Groups was conducted across 40 countries. Endourologists provided real-world procurement data regarding purchase prices, utilization patterns, and equipment-related procedural cost of single-use FURS and FANS between March 2025 and January 2026. All costs were converted to Euros (€). In centres adopting institution-validated reuse protocols, weighted per-procedure costs were calculated by dividing device acquisition costs by the number of effective uses. Countries were stratified according to cost quartiles to assess global variability. Data were collected from 40 countries across Europe, Asia, North and South America, and the Middle East. The median purchase cost of single-use FURS was €676.7 (IQR €579.0-975.0), ranging from €310 in Romania to €1638 in Cyprus. When adjusted for reuse practices, the median equipment-related procedural cost decreased to €425.0 (IQR €216.4-611.2), with values ranging from €92 in Brazil to €1343 in Ireland. The median purchase cost of FANS was €180 (IQR €130-226), ranging from €36 in Uzbekistan to €400 in the United States. Weighted per-procedure costs decreased to a median of €130.5 (IQR €77.5-182.2). The combined equipment cost of FURS and FANS for suction-assisted ureteroscopy ranged from €139.2 in Uzbekistan to €1691 in the United States (USA). Countries adopting cost-conscious reuse strategies achieved substantial reductions in per-procedure expenditure despite high initial acquisition costs. Marked international variability exists in the procurement and equipment-related procedural cost of FURS and FANS, with up to fourfold differences observed between countries. Reuse strategies substantially reduce equipment-related expenditure and may improve the economic sustainability of ureteroscopy. These findings highlight the importance of considering regional cost structures and resource utilization when evaluating the value of emerging endourological technologies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Global variation in acquisition costs of single-use flexible ureteroscopes and flexible navigable access sheaths: an international collaborative analysis from the YAU & EAU Endourology groups.World journal of urology · 2026
- Single-use digital ureteroscopes: which characteristics are essential for the next generation? An international survey.The French journal of urology · 2026
- Evaluation of perioperative outcomes associated with the flexible ureterorenoscopy with flexible and navigable suction ureteral access sheath and reused disposable scopes: a prospective multicentre study by the European Association of Urology and European Association of Urology Section of Endourology.World journal of urology · 2026
- Institutional billed-charge patterns and resource utilization in flexible navigable aspiration sheath-assisted and no-access-sheath ureteroscopy: a single-center descriptive cohort study.International urology and nephrology · 2026
- Multimodal comparison of 19 single-use flexible ureteroscopes: bench testing, operative video assessment, and surgeon ratings.World journal of urology · 2026
- Single-use vs. reusable flexible ureteroscopes: what do our patients prefer?World journal of urology · 2026