Neuroradiology

Endovascular coiling with Target Tetra® Detachable Coils for small (≤ 5 mm) intracranial aneurysms: a prospective single-center registry study.

Kyu Seon Chung, Solbi Kim, Hyun Jin Han, Keun Young Park, Yong Bae Kim, Jung-Jae Kim

Department of Neurosurgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea. · Department of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.

Observational · n=5

Key points

From the paper's conclusion
  • The favorable occlusion rates and acceptable complication profiles suggest that TTDCs are safe and effective for treating small IAs.

Abstract

PURPOSE: Coil embolization of small (≤ 5 mm) intracranial aneurysms (IAs) remains technically challenging. The Target Tetra® Detachable Coil (TTDC) features a tetrahedral configuration designed to facilitate stable coil framing and improve packing stability. Therefore, we prospectively evaluated the safety and efficacy of TTDCs for small IAs. METHODS: In this prospective, single-arm, single-center registry study, patients with small IAs were enrolled between January 2024 and March 2025. Endovascular coiling was performed using TTDCs comprising ≥ 70% of the total coil volume. Primary outcomes were the immediate angiographic occlusion rate and packing density. Secondary outcomes included device-related events, periprocedural complications, and clinical and radiological outcomes at 6 and 12 months. RESULTS: Ninety-five patients with 99 IAs were enrolled, including 98 unruptured IAs and 1 ruptured IA (72.6% female; mean age, 59.5 ± 10.8 years). The technical success rate was 100%. The mean packing density was 32.2 ± 8.7%, with TTDCs comprising 89.5 ± 11.5% of the total coil volume. Wide-neck aneurysms accounted for 98.0% of cases; stent-assisted coiling was used in 34.3%. Device-related events occurred in 7 coils (2.6% of 271 used coils), including failure to load into the microcatheter (n = 5) and difficult retrieval (n = 2). Immediate complete occlusion was achieved in 72.7% of cases and adequate occlusion in 92.9%. At 6 and 12 months, complete occlusion rates were 93.8% and 89.7%, respectively, with no retreatment required. Complications included 1 intraprocedural rupture without sequelae and 2 symptomatic thromboembolic events, one with persistent morbidity at 12 months. There was no procedure-related mortality. CONCLUSIONS: The favorable occlusion rates and acceptable complication profiles suggest that TTDCs are safe and effective for treating small IAs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers