Tiny (≤3 mm) Unruptured Intracranial Aneurysms: A 13-Year Contemporary Insight on Treatment Safety From a Multicenter Registry.
Victor Gabriel El-Hajj, Antony A Fuleihan, Michael Rizzuto, James Castiglione, Joseph Schaefer, Arbaz Momin, Stephanie Serva, Ramesh Grandhi,
Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA. · Department of Neurosurgery, Clinical Neurosciences Center, University of Utah Health, Salt Lake City, Utah, USA.
Key points
From the paper's conclusion- Treatment of tiny unruptured aneurysms remains common despite very low rupture risk. Procedural risks are low and comparable with slightly larger aneurysms. Treatment decisions should integrate both rupture risk and procedural safety, with anterior communicating artery or posterior communicating artery locations and unfavorable baseline functional status representing higher-risk features. When indicated, stent-assisted coiling was independently associated with higher intraoperative complication risk relative to clipping in this cohort.
Abstract
BACKGROUND AND OBJECTIVES: Tiny or very small unruptured intracranial aneurysms (≤3 mm) carry a very low estimated rupture risk, yet many are electively treated. Although factors influencing procedural risks have the potential to guide treatment selection, they remain poorly characterized in this population. METHODS: A retrospective cohort study was conducted using prospectively collected data from the multicenter Stroke Thrombectomy and Aneurysm Registry, including patients treated for unruptured aneurysms between 2013 and 2025. Tiny aneurysms were defined as ≤3 mm. Primary outcomes were intraprocedural and postprocedural complications. Propensity score matching and multivariable logistic regression were performed. RESULTS: Among 5107 treated aneurysms, 783 (15.3%) were tiny. Patients with tiny aneurysms were younger, more often female, and had higher rates of vascular risk factors, prior subarachnoid hemorrhage, or family history of aneurysms (P < .05). Intraoperative complications (5.2% vs 5.1%, P = .91), postprocedural complications (8.4% vs 8.7%, P = .83), in-hospital mortality, and long-term outcomes were comparable with small (3-5 mm) aneurysms. On multivariable analysis, anterior communicating artery (odds ratio [OR] 4.92; 95% CI, 1.34-18.1; P = .016) and posterior communicating artery locations (OR 4.08; 95% CI, 1.40-11.9; P = .010), as well as stent-assisted coiling (OR 3.98; 95% CI, 1.33-11.9; P = .013) predicted intraoperative complications, while favorable preadmission functional status (modified Rankin Scale 0-1; OR 0.40; 95% CI, 0.21-0.76) predicted lower postprocedural complication risk. CONCLUSION: Treatment of tiny unruptured aneurysms remains common despite very low rupture risk. Procedural risks are low and comparable with slightly larger aneurysms. Treatment decisions should integrate both rupture risk and procedural safety, with anterior communicating artery or posterior communicating artery locations and unfavorable baseline functional status representing higher-risk features. When indicated, stent-assisted coiling was independently associated with higher intraoperative complication risk relative to clipping in this cohort.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Safety, efficacy, and angiographic outcomes of endovascular coiling for very small unruptured intracranial aneurysms (≤ 3 mm): subgroup analysis of the ECOSA registry.Frontiers in neurology · 2026
- Do Tiny Intracranial Aneurysms Bleed? A Case Report and Technical Nuances of Microsurgical Clipping of a Tiny Anterior Communicating Artery Aneurysm.Journal of neurological surgery. Part A, Central European neurosurgery · 2026
- Risk and prognostic factors for intraprocedural rupture during endovascular treatment for unruptured intracranial aneurysm: Insights from JR-NET4.AJNR. American journal of neuroradiology · 2026
- Predictors of complete occlusion in endovascular coiling of very small intracranial aneurysms.Neuroradiology · 2026
- Multicenter experience of pipeline embolization device used in small caliber vessels (< 2 mm) for intracranial aneurysm treatment and mid-term resultsFrontiers in Neurology · 2026
- Feasibility and predictors of failure in a distal transradial-first access strategy for endovascular treatment of intracranial aneurysms: A single-center study of 208 cases.Neuroradiology · 2026