CT-based bone mineral density estimation using HU, radiomics, and deep learning.
Satoru Tanioka, Orhun Utku Aydin, Adam Hilbert, Shota Ito, Takahiro Miyazaki, Atsushi Yamamoto, Munenari Ikezawa, Hirofumi Nishikawa,
Charité Lab for Artificial Intelligence in Medicine, Charité - University Medicine Berlin, Berlin, Germany. satoru.tanioka.ns@icloud.com. · Charité Lab for Artificial Intelligence in Medicine, Charité - University Medicine Berlin, Berlin, Germany.
Key points
From the paper's conclusion- We developed an ensemble framework integrating volumetric HU assessment, radiomics, and CNNs to estimate BMD from thoracolumbar junction CT images. External testing across two independent institutions demonstrated promising performance for BMD estimation.
Abstract
PURPOSE: To develop and test models that estimate bone mineral density (BMD) from thoracolumbar junction CT images using Hounsfield unit (HU) assessment, radiomics, and convolutional neural networks (CNNs). METHODS: We retrospectively identified patients who underwent lumbar dual-energy x-ray absorptiometry and CT covering T12 and L1 within 6 months at four hospitals between 2014 and 2025. In total, 465 patients were eligible for T12 analysis, and 448 for L1. Data from two institutions were used for training/validation and data from the other two for external testing. We developed five models: region-of-interest-based HU regression; volume-of-interest (VOI)-based HU regression; radiomics; CNN; and an ensemble combining VOI, radiomics, and CNN. Performance was assessed using mean absolute error (MAE), root mean squared error (RMSE), coefficient of determination (R2), and Bland-Altman limits of agreement (LoA). RESULTS: For T12, the CNN model performed best among the single models (MAE: 0.122, RMSE: 0.157, R2: 0.603), whereas the ensemble model showed a slightly higher MAE (0.128) but lower RMSE (0.154) and higher R2 (0.620). For L1, the radiomics model was the best single model (MAE: 0.124, RMSE: 0.155, R2: 0.582), while the ensemble showed numerically improved performance (MAE: 0.116, RMSE: 0.145, R2: 0.633). Pairwise comparisons showed no significant difference in absolute prediction errors between the ensemble and the best single model at either T12 or L1. CONCLUSION: We developed an ensemble framework integrating volumetric HU assessment, radiomics, and CNNs to estimate BMD from thoracolumbar junction CT images. External testing across two independent institutions demonstrated promising performance for BMD estimation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- CT Radiomics and Machine Learning for Three-Class Bone Density Classification: An Exploratory Comparison Across Lumbar Vertebral Levels.Tomography (Ann Arbor, Mich.) · 2026
- Osteoporosis prediction using lumbar CT Hounsfield units: comparative performance and clinical implications of seven machine learning modelsEuropean Spine Journal · 2026
- Interpretable machine learning for bone mineral density regression via computed tomography radiomics: A retrospective cross-sectional study.The Journal of international medical research · 2026
- An energy-difference indicator for improved quantification of bone mineral density using dual-energy CT.Journal of the Royal Society, Interface · 2026
- Development of a One-Stop Bone Mineral Density Estimation Model Based on Dual-Energy CT with Quantitative Computed Tomography as the Reference Standard.Diagnostics (Basel, Switzerland) · 2026
- Opportunistic application of machine learning for bone health stratification in type 2 diabetes mellitus.Frontiers in endocrinology · 2026