Analytical and bioanalytical chemistry

Synergizing SA-MWCNTs and molecular imprinting for ultra-trace electrochemical sensing of kahweol in serum samples.

Okan Ali Aksoy, Ensar Piskin, Emir Alper Türkoğlu, Ahmet Cetinkaya, M Altay Unal, Burcu Eser, Özgür Eşim, Sibel A Ozkan

Department of Animal Experiments and Research Centre, Gülhane Institute of Health Sciences, University of Health Sciences, Ankara, Türkiye. · Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Türkiye.

Key points

From the paper's conclusion
  • Recovery experiments in real rabbit serum gave an LOD of 2.88 × 10-13 M, and favorable AGREE, AGREE-MIP, and ComplexMoGAPI scores supported the method's greenness.

Abstract

Kahweol (KAH), a bioactive diterpene abundant in unfiltered coffee, has drawn growing pharmacological interest for its anticancer, anti-inflammatory, anti-angiogenic, and metabolic regulatory properties. However, sensitive and rapid methods for its determination in biological matrices remain scarce. This study developed a molecularly imprinted polymer (MIP)-based electrochemical sensor for selective KAH detection using a glassy carbon electrode modified with a sodium alginate-multi-walled carbon nanotube nanocomposite. The imprinted film was formed by electropolymerizing methacrylic acid (MA) with aniline (ANI) as a co-monomer around the KAH template, producing a poly(MA@ANI) recognition layer. Fabrication was optimized for nanocomposite composition, monomer-to-template ratio, polymerization cycles, template removal, and rebinding time. Under optimized conditions, differential pulse voltammetry (DPV) showed a linear range of 2.5 × 10-12 to 2.5 × 10-11 M, with a limit of detection (LOD) of 1.17 × 10-13 M and a quantification limit (LOQ) of 3.51 × 10-13 M. Selectivity tests, including imprinting factor calculations and competitive binding against caffeic acid, caffeine, and interferents, confirmed high specificity toward KAH. Recovery experiments in real rabbit serum gave an LOD of 2.88 × 10-13 M, and favorable AGREE, AGREE-MIP, and ComplexMoGAPI scores supported the method's greenness. Computational modeling (MD, RDF, and DFT) supported the MIP design, revealing stable KAH-monomer complexation through strong hydrogen bonding. This is the first electrochemical determination of KAH in a biological matrix and offers a rapid, cost-effective, green alternative for bioanalytical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Synergizing SA-MWCNTs and molecular imprinting for ultra-trace electrochemical sensing of kahweol in serum samples — Science Skim