A novel multi-aptamer electrospun nanofibrous membrane for simultaneous selective extraction of monoamine neurotransmitters and determination in biological samples by LC-MS.
Xijia Zhang, Junfeng Qin, Chen Ma, Ningning Wang, Yufeng Li, Juanjuan Zhao, Dongsheng Li
School of Pharmacy, Shandong Medical and Pharmaceutical University, No. 318, Gangcheng East Street, Laishan District, Yantai City, Shandong Province, 264003, PR China. · Department of Psychological Clinic, Qingdao Hospital, University of Health and Rehabilitation Sciences (Qingdao Municipal Hospital), Qingdao, Shandong Province, 266071, PR China.
Key points
From the paper's conclusion- The membrane combines high specific surface area, good stability, and aptamer-based specificity, enabling simultaneous and selective extraction of DA and 5-HT from complex samples.
Abstract
Dopamine (DA) and serotonin (5-HT) are key monoamine neurotransmitters, the sensitive determination of which in biological matrices is challenging owing to low concentrations and strong matrix interference. In this study, a multi-aptamer-functionalized electrospun membrane (MA-Au@PVP/PVDF) was developed by simultaneously immobilizing the DA aptamer (Apt-DA) and the 5-HT aptamer (Apt-5-HT) on the membrane surface via Au-S bonds. The membrane combines high specific surface area, good stability, and aptamer-based specificity, enabling simultaneous and selective extraction of DA and 5-HT from complex samples. The enriched analytes were subsequently quantified using liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS). The maximum adsorption capacities of the MA-Au@PVP/PVDF membrane were 190.8 ng/cm2 for 5-HT and 165.1 ng/cm2 for DA, with the adsorption process fitting well to the Langmuir isotherm model (R2 ≥ 0.99). Under optimized extraction conditions, the established method was thoroughly validated in both serum and urine matrices, exhibiting wide linear ranges (2.5-1000 ng/mL, R2 ≥ 0.9905), low limits of quantification (LLOQ 2.5-10 ng/mL), satisfactory intra- and inter-day precision (RSD < 10.54%), and negligible matrix effects (86.37%-108.92%). The recoveries in serum and urine were 88.91%-103.22%, demonstrating its good broad applicability in different matrices. The proposed method was successfully applied to the determination of DA and 5-HT in human urine samples, providing a reliable and efficient pretreatment strategy for trace neurotransmitter analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Bifunctional Fluorescence Aptasensor Based on Target-Induced Strand Displacement Enables Simultaneous Detection of Dopamine and Serotonin in Multiple Body FluidsAnalytical Chemistry · 2025
- Fluorescent aptamer sensing of clenbuterol and salbutamol in artificial urine and construction of a proof-of-concept screening model.Analytical methods : advancing methods and applications · 2026
- Simultaneous hydrophilic interaction liquid chromatography-tandem mass spectrometry quantification of serum neurotransmitters and related metabolites: Development, validation, and application to antenatal depression.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Functionalized Pillar[6]arene Nanomembrane Probe for Ultrasensitive Sensing of Clinically Valuable 1-Methylnicotinamide in Mouse UrineNano Letters · 2026
- Novel Strongly Basic Molecularly Imprinted Solid‐Phase Extraction Sorbent for Simultaneous Determination of Catecholamines and Their Metabolites in UrineJournal of Separation Science · 2026
- Thiol-Ene Click-Derived Porous-Layer Open-Tubular Column for Online Purification and Multiplex LC-MS/MS Analysis of Neurotransmitters.Analytical chemistry · 2026