Analytical methods : advancing methods and applications

Fluorescent aptamer sensing of clenbuterol and salbutamol in artificial urine and construction of a proof-of-concept screening model.

Qinfeng Dong

Public Teaching Department, Linyi Vocational University of Science and Technology, Linyi 276025, Shandong, China. dqinfeng@126.com.

Key points

From the paper's conclusion
  • The results support a candidate front-end triage strategy within the tested artificial matrices: differential signals identify presumptive CLB, SAL-associated high-response and mixed patterns, while any presumptive positive is referred for confirmatory LC-MS/MS rather than used for an anti-doping adjudication.

Abstract

A proof-of-concept differential dual-modal aptamer array was developed for clenbuterol (CLB) and salbutamol (SAL) screening in artificial urine. A CLB-selective aptamer and AP-Ago, a broad β2-agonist aptamer, were coupled to graphene-oxide fluorescence resonance energy transfer and to methylene-blue/ferrocene-labelled gold electrodes. Their four responses formed an analyte fingerprint by combining CLB-selective recognition with the broader response of AP-Ago. Seventy-two blind-coded samples represented six matrices, four screening classes and three independent preparation batches. Batches 1-2 (n = 48) supported model development, whereas batch 3 (n = 24; six samples per class) was locked for external assessment. Weighted calibration gave provisional procedural limits of detection of 0.083 ng mL-1 for CLB and 0.164 ng mL-1 for SAL. Mean external prediction-to-reference ratios were approximately 96% for CLB and 81% for SAL, distinct from controlled spike recoveries; intraday precision was 3.7% and interbatch precision was 5.8%. Against isotope-dilution LC-MS/MS, concordance correlation coefficients were 0.939 for CLB and 0.793 for SAL. A regularized multinomial logistic model achieved external balanced accuracy of 0.833, macro-F1 of 0.836 and Matthews correlation coefficient of 0.791. The reported bootstrap 95% confidence interval for balanced accuracy was 0.656-0.969, reflecting the small external set. The results support a candidate front-end triage strategy within the tested artificial matrices: differential signals identify presumptive CLB, SAL-associated high-response and mixed patterns, while any presumptive positive is referred for confirmatory LC-MS/MS rather than used for an anti-doping adjudication.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Fluorescent aptamer sensing of clenbuterol and salbutamol in artificial urine and construction of a proof-of-concept screening model — Science Skim