Expanded evaluation of a robust on-line sample cleanup-LC-MS platform suited for new approach methodologies (NAM).
Marcus Kamande, Julie Bekkhus, Stian Kogler, Aysan Safavi, Mads T S Gisle Johnsen, Patrik Appelblad, Steven Ray Wilson, Hanne Røberg-Larsen
Section of Chemical Life Science, Department of Chemistry, University of Oslo, Oslo, Norway. · School of Engineering and Natural Sciences, University of Iceland, VR-II, Hjardarhaga 6, 107, Reykjavik, Iceland.
Key points
From the paper's conclusion- Taken together, these results demonstrate that AFFL provides a robust, low-waste, and scalable LC-MS-based workflow for chemical analysis of NAM-derived samples.
Abstract
Sample preparation in bioanalysis can require significant numbers of (manual) steps and consumables. Such procedures can be bottlenecks regarding cost, throughput, and greenness. This is also the case for analysis of new approach methodologies (NAMs) such as organoids and organ-on-a-chip systems. In this context, approaches tailored for measuring drugs in NAM-related cell culture media (CCM) are being developed. For mass spectrometry-based analysis, automated filtration/filter backflush solid-phase extraction liquid chromatography AFFL-SPE-LC is utilized. Case studies have shown that the "AFFL" platform allows for vast reductions in sample preparation efforts, as the "self-cleaning" filtration features and SPE conditions remove potentially clogging/contaminating materials from samples of biological origin, e.g., the salt and protein content in CCM. Here, broader demonstrations of the AFFL platform's traits for CCM analysis are provided, employing an extended panel of hydrophobic small-molecule drugs. The investigated AFFL platform shows reproducible chromatographic performance, as well as fit-for-purpose inter-matrix and inter-column robustness. Hundred-scale injections can be performed with satisfactory repeatability (e.g., retention time RSDs < 1%), with limited interference from the various CCM matrices investigated. Practical NAM applications are also demonstrated. The approach has clear advantages in greenness, obtaining an AGREE prep score of 0.71, contrasting the < 0.55 scores of more conventional/commercial approaches. The plastic consumable usage of our approach is 28 g/100 samples, a nearly 20-fold improvement over a previously established benchmark (500 g/100 samples). Taken together, these results demonstrate that AFFL provides a robust, low-waste, and scalable LC-MS-based workflow for chemical analysis of NAM-derived samples.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Covalent Organic Framework-Based Solid Phase Microextraction Coating for Rapid Screening and Quantification of Drugs of Abuse and Artificial Sweeteners in Surface Waters.Analytical chemistry · 2026
- Toward operationally reliable PFAS quantification in complex liver matrices: Systematic optimization of commercial Cleanup cartridges for LC-MS/MS analysis.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- B-371 Streamlining Immunosuppressant Quantification: Evaluation of Automated Magnetic Bead–Based Solid-Phase Extraction (mSPE) for Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)Clinical Chemistry · 2026
- Automated all-in-one device for handling Magnetic Bead-Based Samples in immunoassays.Device · 2026
- A multi-platform characterization of aggregation in morpholino oligonucleotide drug products: From soluble aggregates to subvisible particles.Journal of pharmaceutical sciences · 2026
- Systematic Assessment of Matrix Effect, Recovery, and Process Efficiency Using Three Complementary Approaches: Implications for LC-MS/MS Bioanalysis Applied to Glucosylceramides in Human Cerebrospinal FluidACS Omega · 2025