Vaginal Canal Segmentation with nnU-Net Algorithm from MRI Defecography for Biomechanical Analysis.
Serdar Aydın, Ahmet Furkan Sarıkaya, Eren Karakuş, Elif Sachinler, Büşra Yalçın, Emre Balık, Çiğdem Gündüz Demir
Department of Obstetrics and Gynecology, Koç University School of Medicine, Istanbul, Turkey. serdariks@yahoo.com. · Simicad Medical Technologies, Istanbul, Turkey.
Key points
From the paper's conclusion- The nnU-Net framework enables rapid, accurate, and reproducible segmentation of the gel-distended vaginal lumen from MRD images. This automated pipeline may facilitate standardized three-dimensional measurement of the visible vaginal cavity and provide geometry for patient-specific biomechanical modeling.
Abstract
INTRODUCTION AND HYPOTHESIS: Accurate three-dimensional segmentation of the vaginal canal is essential for patient-specific pelvic floor modeling, biomechanical analysis, and the development of personalized intravaginal devices. However, manual segmentation of magnetic resonance defecography (MRD) images is time-consuming and prone to observer variability. This study aimed to develop and evaluate an automated deep learning pipeline using the nnU-Net framework for vaginal canal segmentation from MRD images. METHODS: In this retrospective study, 47 women who underwent MRD for symptoms of pelvic floor dysfunction were included. The vaginal canal was manually annotated on three-dimensional T2-weighted MRD volumes using 3D Slicer to generate ground-truth binary masks. A 3D full-resolution nnU-Net model was trained and evaluated using fivefold cross-validation. Segmentation accuracy was assessed using the Dice similarity coefficient (DSC) and intersection over union (IoU). Predicted masks were further processed using hole filling, marching cubes surface reconstruction, and Taubin smoothing to generate three-dimensional meshes and extract vaginal volume and surface area. RESULTS: The nnU-Net model achieved high segmentation accuracy, with a mean DSC of 0.9714 and a mean IoU of 0.9675. Automated segmentation of a full 3D MRD volume required < 1 s, compared with approximately 30-45 min for manual segmentation. The mean vaginal volume was 38.74 ± 13.98 cm3, and the mean vaginal surface area was 82.31 ± 19.31 cm2. CONCLUSIONS: The nnU-Net framework enables rapid, accurate, and reproducible segmentation of the gel-distended vaginal lumen from MRD images. This automated pipeline may facilitate standardized three-dimensional measurement of the visible vaginal cavity and provide geometry for patient-specific biomechanical modeling.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automated MRI-Based Segmentation of the Cranio-Cervical Venous System Using a Dedicated Deep Learning PipelinemedRxiv · 2026
- Three-dimensional automatic segmentation of root canals with focus on the second mesiobuccal canal using nnU-Netv2 on CBCT images: deep learning approachBMC Oral Health · 2026
- Multi-centre Validation of Automated Outer-to-Outer Wall Segmentation of Infrarenal Abdominal Aortic Aneurysms Using a nnU-Net Based Model.Journal of imaging informatics in medicine · 2026
- An automated deep learning-based pipeline for 3D characterisation of the murine upper airway from micro-CT.Frontiers in medical technology · 2026
- Clinical evaluation of nnU-Net-based segmentation for enhanced MRCP maximum intensity projection visualization.Magma (New York, N.Y.) · 2026
- Deep learning classification of benign and malignant adnexal lesions on pelvic MRI.European journal of radiology · 2026