Effect of periprosthetic greater trochanter fractures (Vancouver AG) on primary stability of the femoral stem in total hip arthroplasty: a biomechanical micromotion analysis.
Jan Bruder, Manuel Goronzi, Adrian Cavalcanti Kußmaul, Jan Wulf, Florian Pachmann, Boris Michael Holzapfel, Wolfgang Böcker, Manuel Kistler
Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany. jan.bruder@med.uni-muenchen.de. · Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Marchioninistr. 15, 81377, Munich, Germany.
Key points
From the paper's conclusion- Vancouver AG fractures did not significantly affect the primary anchorage zone of the CLS Spotorno stem in this study. Further studies with larger sample sizes and varying implant designs are needed to confirm these findings and their clinical implications.
Abstract
PURPOSE: Primary stability is a crucial factor for the long-term success of cementless total hip arthroplasty (THA). Periprosthetic fractures represent an important cause of loss of primary implant stability. While Vancouver AG fractures rarely lead to stem loosening, their effect on the metaphyseal anchoring of the stems has not yet been investigated. The present study aimed to evaluate the influence of a Vancouver AG fracture on the primary stability of the CLS Spotorno stem. METHODS: Six fourth-generation composite femora were implanted with cementless CLS Spotorno stems (Zimmer, Warsaw, USA). Primary stability was determined by three-dimensional digital image correlation under dynamic loading conditions (300-1700 N, 1 Hz) simulating physiological gait. Micromotion was recorded at six standardized measurement points (proximal, mid, distal, medial and ventral) before and after a simulated Vancouver AG fracture. Data was statistically analyzed using paired one-sided t-tests (α = 0.05). RESULTS: The results revealed no significant increase in micromotion at the primary anchorage zone of the stem. However, a non-significant increase in micromotion was observed at the prosthesis tip (DGventral and DGmedial), where the micromotion values increased from 164.4 μm (± 59.6 μm) and 140.4 μm (± 75.6 μm) to 193.1 μm (± 48.8 μm) and 186.9 μm (± 60.5 μm), respectively. CONCLUSION: Vancouver AG fractures did not significantly affect the primary anchorage zone of the CLS Spotorno stem in this study. Further studies with larger sample sizes and varying implant designs are needed to confirm these findings and their clinical implications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fracture Morphology and Extraction-Related Femoral Damages in Short Versus Standard Cementless Stems: Analyses of Vancouver B2 Fractures and Well-Fixed Nonfracture Revisions.Arthroplasty today · 2026
- Ten-year migration analysis of a cementless metaphyseal-anchored short femoral stem in total hip arthroplasty.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2026
- Periprosthetic Femoral Fracture in Hip Arthroplasty Using Cemented Stems: Toward a Construct-Level and Time-Dependent Perspective.Bioengineering (Basel, Switzerland) · 2026
- Early Periprosthetic Femoral Fractures and Stem Subsidence After Direct Anterior Total Hip Arthroplasty Using a Collared, Fully Hydroxyapatite-Coated Stem.Journal of orthopaedics · 2026
- Fractures Around Collared and Collarless Hip Stems Initiate in High Strain Regions: A Combined Cadaveric Experiment and Finite Element Analysis.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Influence of stem undersizing during direct anterior approach for total hip arthroplasty on periprosthetic bone biomechanics : a finite element analysis.Bone & joint research · 2026