Sandeep Singh, Supratik Sen, Abhay Kumar Singh, Dipesh, Manindra Bhushan, Kothanda Raman Samuvel, Soniya Pal, Sarthak Tandon,
Department of Radiation oncology, Amrita School of Medicine, Amrita Vishwa Vidyapeetham, Faridabad, Haryana, India. sandeep.singh82a@gmail.com. · Department of Radiation Oncology, Dr. B. Borooah Cancer Institute, Guwahati, Assam, India.
Key points
From the paper's conclusion- Dosimetric outcomes improved over the study period, but these changes coincided with reduced target volume, treatment technique transition, TPS upgrade, and workflow maturation. The findings should be interpreted as multifactorial rather than as evidence of an isolated technological effect.
Abstract
OBJECTIVE: This study aimed to quantify changes in plan quality for head and neck reirradiation (reRT) on a constant C‑arm platform. METHODS: This retrospective study included 775 patients treated on a TrueBeam STx (Varian Medical Systems, Palo Alto, USA) between 2015 and 2025. Delivery transitioned from fixed-field IMRT during 2015-2019 to VMAT during 2020-2025. Planning was performed in Eclipse, with one upgrade from version 11.0.31 to 15.6.06. Endpoints included PTV D95, D98, D50, D2; different gradient indices; and doses to the spinal cord, brainstem, carotids, mandible, oral cavity, and DARS. Year-wise differences were tested using ANOVA with Bonferroni-adjusted pairwise comparisons and nonparametric sensitivity analyses. Linear models included calendar year and the log-transformed PTV volume. RESULTS: Mean PTV D95 increased from 96.4 ± 0.5% to 99.6 ± 0.2%, while D2 decreased from 108.5 ± 1.6% to 104.0 ± 0.1%. Gradient indices decreased over the study period, indicating reduced dose spillage and steeper dose fall-off. Spinal cord and brainstem doses also declined substantially, with additional reductions in oral cavity and DARS doses. All four primary target endpoints showed significant year effects after multiplicity adjustment and nonparametric sensitivity testing. The PTV volume decreased from 700.2 ± 16.7 cc to 250.4 ± 14.7 cc, representing an approximately 64% reduction, and likely contributed to the observed improvements in gradient indices and OAR sparing. Temporal associations persisted after adjustment for the log-transformed PTV volume. CONCLUSION: Dosimetric outcomes improved over the study period, but these changes coincided with reduced target volume, treatment technique transition, TPS upgrade, and workflow maturation. The findings should be interpreted as multifactorial rather than as evidence of an isolated technological effect.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dose fall-off index (DFI): An organ-centric metric for spatial dose gradient evaluation in head and neck IMRT and VMAT.Journal of cancer research and therapeutics · 2026
- Long-term dosimetric superiority of VMAT over 3D-CRT in pediatric focal brain irradiation: a comprehensive 15-year institutional analysisPathology & Oncology Research · 2026
- A Unified Planning Platform Comparison of VMAT, Helical Tomotherapy, and IMRT in Nasopharyngeal Carcinoma: Dosimetric Superiority and Organ Sparing AnalysisTechnology in Cancer Research & Treatment · 2026
- Toward optimal radiotherapy in tongue cancer: a comparative study of IMRT and VMAT.Radiological physics and technology · 2026
- Is full re-optimization necessary in adaptive radiotherapy for head and neck cancer? A systematic review of dosimetric and clinical outcomes.Journal of cancer research and therapeutics · 2026
- Evaluation of feasibility DVH-guided re-optimization for RapidPlan-generated prostate VMAT plans.Medical dosimetry : official journal of the American Association of Medical Dosimetrists · 2026