Intra-adaptational motion during online adaptive radiotherapy: analysis of couch shifts and implications for margin design.
Johannes Hecking, Hanna Malygina, Jan Palm, Bryan Salazar Zuniga, Sven Knobe, Yvonne Dzierma, Markus Hecht, Hendrik Auerbach
Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. 100, 66421, Homburg/Saar, Germany. jo.hecking@gmail.com. · Department of Radiotherapy and Radiation Oncology, Saarland University Medical Centre, Kirrberger Str. 100, 66421, Homburg/Saar, Germany.
Key points
From the paper's conclusion- Intra-adaptational motion varies substantially between patients, supporting the consideration of patient-specific margins. Verification CBCT2 is essential in oART due to potentially large positional shifts occurring during the adaptation process. The calculated margins represent upper bounds for motion-related margins, as they incorporate registration errors and cover longer intervals than actual beam delivery.
Abstract
PURPOSE: Online adaptive radiotherapy (oART) minimizes inter-fractional variation, yet intra-fractional motion (IFM) remains a source of uncertainty. We quantified intra-adaptational motion (IAM) using routinely recorded couch shifts between pre-adaptation (CBCT1) and pre-treatment (CBCT2) scans to derive motion-related components of the CTV-PTV margins in a large clinical cohort. METHODS: We retrospectively analyzed 1378 fractions from 69 prostate cancer patients treated with 60 Gy in 20 fractions as oART on the Varian Ethos platform (vision 1.1; Varian Medical Systems, Palo Alto, CA, USA). Couch shifts were calculated based on rigid registration targeting the CTV. Systematic and random errors were calculated for right-left (RL), anterior-posterior (AP), and superior-inferior (SI) directions. Margins were estimated using the van Herk formula. Correlations between couch shifts and the CBCT1-CBCT2 time interval were assessed using Spearman's ρ. RESULTS: Couch shifts showed substantial inter-patient variability. Population mean, systematic, and random errors ranged from 0.05 to 1.4 mm, 0.6 to 1.3 mm, and 1.0 to 1.4 mm, respectively. The mean adaptation time was 17.5 ± 5.1 min (median: 16.6 min, interquartile range [IQR]: 14.0-20.3 min). The resulting IAM-related margins were 2.3 (R), 2.2 (L), 2.2 (S), 3.2 (I), 2.9 (A), and 5.7 mm (P). Positive correlations were observed between the time interval and motion in AP (ρ = 0.26), SI (ρ = 0.30), and vector magnitude (ρ = 0.29; all p < 0.001). CONCLUSION: Intra-adaptational motion varies substantially between patients, supporting the consideration of patient-specific margins. Verification CBCT2 is essential in oART due to potentially large positional shifts occurring during the adaptation process. The calculated margins represent upper bounds for motion-related margins, as they incorporate registration errors and cover longer intervals than actual beam delivery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Online adaptive radiotherapy in pelvic and thoracic cancers - comparing toxicities, clinical outcomes and technical parameters between conventional image-guided radiotherapy and online adaptive radiotherapy - the study protocol for the prospective, registry-based cohort study (PRoART).BMC medical imaging · 2026
- Adaptive Radiotherapy: Principles, Technologies, Clinical Applications, and Future Directions — A Comprehensive ReviewInternational Journal of Drug Delivery Technology · 2026
- Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCTJournal of Applied Clinical Medical Physics · 2026
- Influence of gating and drift correction on prostate cancer treatment margins on a 1.5 T magnetic resonance linear accelerator.Physics and imaging in radiation oncology · 2026
- Dosimetric Validation of Ethos Online Adaptive Radiotherapy for Prostate Cancer: An End-to-End Phantom Study.Life (Basel, Switzerland) · 2026
- Exploring a hybrid workflow on current adaptive radiotherapy systems.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026