Performance Evaluation and Surrogate Optimization of an NCW–VFD Stiffness–Damping Zoned Seismic Mitigation System for Laboratory Buildings With Open Lower Stories
Yun Chen, Wenjun Mao, Chuang Yang, Ming Zhou, Zitong Yang, Hao Xu
Key points
From the paper's conclusion- The results show that NCW + VFD keeps the drift demand close to BRB only and the acceleration demand close to VFD only.
Abstract
Laboratory buildings with open lower stories require simultaneous control of lower‐story drift and floor acceleration in equipment‐sensitive upper stories, whereas a single stiffness‐ or damping‐based control mechanism is often insufficient. This study proposes a stiffness–damping zoned seismic mitigation system. It combines lower‐story nonbuckling corrugated steel shear walls (NCWs) and upper‐story viscous fluid dampers (VFDs). The NCWs provide lateral stiffness and share lower‐story shear. The VFDs dissipate seismic input energy and reduce peak floor acceleration. A laboratory building in a high seismic region is used as the prototype. Three schemes are compared: VFD‐only, BRB‐only, and NCW + VFD. Component‐level tests were conducted to verify the mechanical properties of the NCWs and VFDs adopted in the numerical model. Nonlinear time‐history analysis, incremental dynamic analysis, fragility analysis, and Kriging‐based multiobjective optimization are performed. The results show that NCW + VFD keeps the drift demand close to BRB only and the acceleration demand close to VFD only. The acceleration safety factor reaches 2.00. The optimized scheme reduces peak floor acceleration by 3.45% and device demand by 13.43%. The proposed system provides a practical solution for function‐sensitive buildings with large‐span lower stories.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Shake Table and Numerical Evaluation on the Seismic Performance of Elastic‐boundary Ceiling SystemsEarthquake Engineering & Structural Dynamics · 2026
- Nonstationary Stochastic Seismic Optimization of Base‐Isolated Nuclear Power Plant Equipped With Negative Stiffness Amplifying Damper Considering Dynamic Soil–Structure‐InteractionEarthquake Engineering & Structural Dynamics · 2026
- Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification RegimesBuildings · 2026
- Vertical seismic isolation systems for new and existing structures in process and nuclear power plantsEngineering Structures · 2026
- Design Strategy of Nonlinear Energy Sink Inerter for Vortex-Induced Vibration Mitigation of Long-Span BridgesJournal of Structural Engineering · 2026
- Influence of input motion uncertainty in developing slope-specific seismic fragility curves based on nonlinear finite element simulationsNatural Hazards · 2026