Buildings

Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes

Ertuğrul Çambay, Cenk Çontay

Key points

From the paper's conclusion
  • Notably, under soft soil (ZE) excitations where unprotected bare frames develop severe interstory drift concentrations (up to 3.18%), the FVD systems consistently restrict maximum interstory drift ratios (IDRs) below the 0.80% damage-control limit, keeping peak drift demands within the threshold conventionally associated with elastic or near-elastic frame response, thereby indicating a low likelih

Abstract

This study investigates the dynamic efficacy of Fluid Viscous Dampers (FVDs) in mitigating lateral story drift and attenuating seismic base shear forces in multi-story steel moment-resisting frames (MRFs) subjected to contrasting geotechnical site conditions. Archetype steel structures with 5, 10, and 15 stories were designed in full compliance with the Turkish Building Earthquake Code (TBDY-2018) and AISC 360-16 specifications, considering hard rock (ZA) and soft, deep sedimentary soil deposits (ZE) for high-seismicity coordinates along the East Anatolian Fault zone (Pazarcık, Kahramanmaraş). A suite of 11 real earthquake acceleration pairs (22 horizontal components) compiled from the AFAD TADAS database was spectrally matched to code-compliant target elastic response spectra using continuous wavelet transforms. Direct integration nonlinear time-history analyses (NL-THA) were executed using the Newmark average acceleration method. Modal eigenvalue analyses confirm that supplemental diagonal FVDs preserve the fundamental natural vibration periods of the frames (T1 = 0.70 s, 1.53 s, and 1.53 s for the 5-, 10-, and 15-story archetypes, respectively) without imposing secondary elastic stiffness penalties. The nonlinear dynamic findings demonstrate that FVD integration reduces peak lateral floor displacements by 54.59% to 88.05% and suppresses maximum base shear demands by 69.10% to 85.29% across all heights and shaking directions. Notably, under soft soil (ZE) excitations where unprotected bare frames develop severe interstory drift concentrations (up to 3.18%), the FVD systems consistently restrict maximum interstory drift ratios (IDRs) below the 0.80% damage-control limit, keeping peak drift demands within the threshold conventionally associated with elastic or near-elastic frame response, thereby indicating a low likelihood of plastic hinge formation and precluding second-order P − Δ collapse mechanisms.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers