Seismic Drift Mitigation and Base Shear Attenuation in Multi-Story Steel Moment Frames Equipped with Fluid Viscous Dampers Across Contrasting Soil Amplification Regimes
Ertuğrul Çambay, Cenk Çontay
Key points
From the paper's conclusion- Notably, under soft soil (ZE) excitations where unprotected bare frames develop severe interstory drift concentrations (up to 3.18%), the FVD systems consistently restrict maximum interstory drift ratios (IDRs) below the 0.80% damage-control limit, keeping peak drift demands within the threshold conventionally associated with elastic or near-elastic frame response, thereby indicating a low likelih
Abstract
This study investigates the dynamic efficacy of Fluid Viscous Dampers (FVDs) in mitigating lateral story drift and attenuating seismic base shear forces in multi-story steel moment-resisting frames (MRFs) subjected to contrasting geotechnical site conditions. Archetype steel structures with 5, 10, and 15 stories were designed in full compliance with the Turkish Building Earthquake Code (TBDY-2018) and AISC 360-16 specifications, considering hard rock (ZA) and soft, deep sedimentary soil deposits (ZE) for high-seismicity coordinates along the East Anatolian Fault zone (Pazarcık, Kahramanmaraş). A suite of 11 real earthquake acceleration pairs (22 horizontal components) compiled from the AFAD TADAS database was spectrally matched to code-compliant target elastic response spectra using continuous wavelet transforms. Direct integration nonlinear time-history analyses (NL-THA) were executed using the Newmark average acceleration method. Modal eigenvalue analyses confirm that supplemental diagonal FVDs preserve the fundamental natural vibration periods of the frames (T1 = 0.70 s, 1.53 s, and 1.53 s for the 5-, 10-, and 15-story archetypes, respectively) without imposing secondary elastic stiffness penalties. The nonlinear dynamic findings demonstrate that FVD integration reduces peak lateral floor displacements by 54.59% to 88.05% and suppresses maximum base shear demands by 69.10% to 85.29% across all heights and shaking directions. Notably, under soft soil (ZE) excitations where unprotected bare frames develop severe interstory drift concentrations (up to 3.18%), the FVD systems consistently restrict maximum interstory drift ratios (IDRs) below the 0.80% damage-control limit, keeping peak drift demands within the threshold conventionally associated with elastic or near-elastic frame response, thereby indicating a low likelihood of plastic hinge formation and precluding second-order P − Δ collapse mechanisms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Experimental and Numerical Evaluation of Passive Damping in a Slender Steel FrameMachines · 2026
- Influence of Friction and Fluid Viscous Dampers on the Seismic Response of a Typical RC School Building with Different Concrete StrengthsBuildings · 2026
- Nonlinear Time-History Analysis of Seismic Performance of RC Frames Equipped with Buckling-Restrained Braces Versus Viscous Fluid DampersJournal of Composites Science · 2026
- Frequency-Dependent Slope Stability Under Earthquake Loading: A Parametric Study with Hybrid FEM–LEMGeosciences · 2025
- Linear and Nonlinear Site Responses Revealed by Single-Station Time–Frequency Analysis: Application in Southeastern TürkiyeBulletin of the Seismological Society of America · 2026
- Seismic upgrade of isolated bridges with supplemental vibration control devicesSoil Dynamics and Earthquake Engineering · 2025