Investigation of a Self-Centring Beam-to-Beam Connection and Its Structure-Level Seismic Response
Yun Huang, Junhong Dong, Tian Wang, Lexuan Huang, Huaxiang Su
Key points
From the paper's conclusion- The results showed that increasing the initial gap extended the reduced-stiffness stage and slightly decreased the ultimate moment capacity.
Abstract
An experimental and numerical investigation was conducted on a beam-to-beam self-centring connection incorporating superelastic shape memory alloy (SMA) plates and steel disc springs, hereafter termed the SMA-plate connection (SPC). The cyclic behaviour of a gap-minimised SPC specimen was characterised experimentally and compared with previously published results for a different gapped configuration (SPC-G). The gap-minimised specimen exhibited a flag-shaped hysteretic response, small residual deformation, and moderate energy dissipation. By contrast, SPC-G exhibited a low-stiffness stage during early loading and final unloading. This stage increased the deformation required to engage the principal resisting mechanism and lowered the initial stiffness. However, the self-centring response was not markedly degraded. A refined three-dimensional finite element (FE) model was developed. Its accuracy was assessed by comparing its predictions with the connection-level test results. Additional FE parametric analyses were conducted to further investigate the influence of the initial connection gap on the connection response. The results showed that increasing the initial gap extended the reduced-stiffness stage and slightly decreased the ultimate moment capacity. A computationally efficient connector-beam-truss model was then established to reproduce the principal hysteretic features and the gap-closing mechanism. The simplified model was used to analyse three-storey prototype self-centring steel frames with and without connection gaps under 30 mainshock-aftershock sequences. For the prototype frame with the adopted uniform connection gap, the analyses indicated higher maximum interstorey drift (MID) responses than those of the frame without gaps. The additional MID amplification associated with aftershocks was nevertheless smaller in the gapped frame. However, these differences are descriptive, as no statistical significance tests were performed. Residual drifts remained small and comparable for both frames. No consistent increase in residual drift was observed under the mainshock–aftershock sequences. For the analysed prototype and selected ground-motion sequences, the adopted connection gaps had only a limited influence on the system-level residual-drift response.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Seismic fragility assessment of self-centering braced steel frames with cyclic degradation under mainshock-aftershock sequencesStructures · 2026
- Self-Centering Energy Dissipative Braces for Seismic Resilience: Evolution, Mechanical Behavior, Experimental Validation, and Engineering ApplicationsBuildings · 2026
- Testing, Modeling, and Application of a Two‐Stage Self‐Centering Brace for Seismic Resilience Enhancement of Rocking Core SystemEarthquake Engineering & Structural Dynamics · 2025
- Seismic Performance of Reduced‐Strength Steel MRFs With SMA‐Based Superelastic Friction Dampers: An Experimental InvestigationEarthquake Engineering & Structural Dynamics · 2026
- EVALUATION OF PLASTIC DEFORMATION CAPACITY OF BEAM-TO-COLUMN CONNECTIONS WITH H-SHAPED MEMBERS IN EXISTING STEEL BUILDINGJournal of Structural and Construction Engineering (Transactions of AIJ) · 2026
- Experimental investigation of seismic performance of reinforced concrete beam‐column joints with hybrid connections combining friction side plates and composite energy‐dissipation boxesStructural Concrete · 2026