Development and Validation of Liquid Chromatography–Tandem Mass Spectrometry Method for Quantification of Lazertinib in Plasma Samples and Pharmacokinetic Study in Rabbits
Balakrishna Attuluri, Mithun Rudrapal, Venkateswararao B, Rajya Lakshmi Koduru
Key points
From the paper's conclusion- The developed technique was subjected to method validation as per the US Food and Drug Administration bioanalytical guidelines and demonstrated suitability for the routine quantification of lazertinib in plasma and pharmacokinetic assessment in rabbits.
Abstract
The aim of the present study was to establish a precise, linear, and specific liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC–ESI–MS/MS) technique for the quantitative estimation of lazertinib in plasma of rabbits. Analyte separation was accomplished on a Phenomenex C18 (50 × 4.6 mm, 2.1 µm) column, employing an isocratic mobile phase composed of 0.1% formic acid and methanol (15:85, v/v), with a 0.6 mL/min flow rate. Detection was performed in LC–ESI–MS/MS by multiple reaction monitoring specimode, with ionic transitions m/z 555.27 → 501.27 for lazertinib and m/z 494.27 → 451.23 for imatinib, which was utilized as the internal standard. A lower limit of quantification of 13 ng/mL was established with excellent selectivity, enabling efficient separation of lazertinib from endogenous plasma components under optimized LC–MS/MS conditions. Linearity standards were performed at 13–520 ng/mL, and the regression analysis yielded y = 0.0028 x + 0.0038, with r 2 value of 0.9998. The matrix effect showed %CV values of 3.40% (low quality control [low‐QC]) and 3.70% (high‐QC). The mean recovery values for lazertinib were 95.29% at high‐QC (390 ng/mL), 96.84% at mid‐QC (260 ng/mL), and 94.33% at low‐QC (36.4 ng/mL). Precision results for QC levels ranged from 2.00% to 4.03%, well within acceptance limits. Negligible carry‐over was observed, and the analyte demonstrated acceptable stability under all evaluated storage and processing conditions. After being administered to rabbits, the validated technique was tested for lazertinib's pharmacokinetic properties. T max , C max , and T 1/2 of the lazertinib formulation were 2 ± 0.02 h, 440.12 ± 14.60 ng/mL, and 2.195 ± 0.05 h, respectively. AUC 0‐∞ for the lazertinib formulation was 1220.515 ± 49.10 ng/mL·h. The developed technique was subjected to method validation as per the US Food and Drug Administration bioanalytical guidelines and demonstrated suitability for the routine quantification of lazertinib in plasma and pharmacokinetic assessment in rabbits.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a Liquid Chromatography‐Electrospray Ionization‐ Tandem Mass Spectrometry Method for the Quantification of Tovorafenib in Human Plasma: Application of Kinetic Study in Healthy RabbitsSEPARATION SCIENCE PLUS · 2026
- Sensitive LC–MS/MS Method for Simultaneous Quantification of Alectinib and Its Major Metabolite M4 in Limited‐Volume Human PlasmaBiomedical Chromatography · 2026
- Pharmacokinetic Study of Nintedanib and Its Metabolites in Rats Determined by LC–MS/MSBiomedical Chromatography · 2026
- Development and Validation of a UPLC-MS/MS Method for Simultaneous Quantification of Ensartinib and Its Major Metabolite M465 in Rat Plasma and Application to Pharmacokinetic Studies.Drug design, development and therapy · 2026
- An automated column-switching LC-MS/MS method using immobilized trypsin for the rapid quantification of pembrolizumab in human serum.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026
- Determination of Apalutamide in Human Plasma by Sensitive LC‐MS/MS Method and the Application to a Bioequivalence StudyBiomedical Chromatography · 2026