Identification and Structural Elucidation of Potential Degradation Impurities in Testosterone Topical Formulation Using LC–MS, NMR and Evaluation of Genotoxicity by Using Knowledge‐Based (Derek Nexus) and a Statistical Method‐Based (TOPKAT) Silico Tools
Venugopalarao Mukkapati, Venkata Kanaka Srivani Maddala, Hanimi Reddy Bapatu, Praveen Kumar Subbappa
Key points
From the paper's conclusion- Three degradation impurities, identified as 6β‐hydroxy‐testosterone, 6β‐hydroperoxy‐testosterone, and 6‐keto‐testosterone impurities with molecular masses of 304.42, 320.20, and 302.41, were isolated and characterized using preparative chromatographic, high‐resolution mass spectrometric, and nuclear magnetic resonance techniques, followed by in silico (Q)SAR assessment of their potential genotoxic
Abstract
While developing a topical gel 1% w/w dosage form, significant unknown impurities were observed above their threshold during shelf‐life determination, with relative retention time (RRT) of 0.66, 0.67, and 0.71 in accelerated stability conditions of 40°C temperature and 75% relative humidity sample. Due to the importance of pharmaceutical quality and purity, impurities during manufacture or storage might cause serious side effects. If an unknown impurity exceeds its threshold limits during product stability testing, its structure must be determined to assess the potential risks. Impurities were separated by gradient HPLC on a Kinetex C18 column with 0.1% formic acid mobile phases, detected at 245 nm. Structural characterization was done using liquid chromatography with mass spectrometry (LC–MS) and 1 H NMR (400 MHz). This study investigated and characterized degradation impurities observed during stability testing of a testosterone topical gel formulation. Three degradation impurities, identified as 6β‐hydroxy‐testosterone, 6β‐hydroperoxy‐testosterone, and 6‐keto‐testosterone impurities with molecular masses of 304.42, 320.20, and 302.41, were isolated and characterized using preparative chromatographic, high‐resolution mass spectrometric, and nuclear magnetic resonance techniques, followed by in silico (Q)SAR assessment of their potential genotoxicity using Deductive Estimate of Risk from Existing Knowledge (Derek) Nexus and Toxicity Prediction using Komputer Assisted Technology (TOPKAT) silico tools‐based knowledge and statistical methods. In silico toxicity evaluation with TOPKAT and Derek Nexus indicated that the testosterone impurities at RRT of 0.66, 0.67, and 0.71 are non‐mutagenic, corroborating their designation as ICH M7 Class 5 impurities.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Review on Analytical Insights into Impurity Profiling of Selected Anticancer Agents: Tinibs and Taxanes.Critical reviews in analytical chemistry · 2026
- Development and Validation of a Stability‐Indicating HPLC Method for Degarelix and Characterization of Its Degradation Impurities Using LC–MS, 1 H NMR, and FTIR TechniquesBiomedical Chromatography · 2026
- Novel Potential Genotoxic Impurity Identification and Quantification by Using Quality by Design Approach in Angiotensin II Receptor BlockerSeparation Science Plus · 2025
- Detection and structural elucidation of preservative-excipient isomeric esters of benzyl alcohol and citric acid in a topical hydrogel formulation on accelerated stability by LC-MS and benchtop NMR spectroscopy.Journal of pharmaceutical and biomedical analysis · 2026
- From "Undetectable" to "Sensitive Detection": Advances in Derivatization Techniques for LC-MS Analysis of Genotoxic Impurities.Molecules (Basel, Switzerland) · 2026
- Comprehensive composition analysis of doxorubicin HCl liposomes.Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026