A Signal-Amplified Lateral Flow Immunoassay Platform Integrating Palladium-Platinum Bimetallic Nanoparticles for P1NP Detection in Osteoporosis Treatment Monitoring.
Cheng-Yang Tung, Tsung-Ting Tsai, Ping-Yeh Chiu, Natalie Yi-Ju Ho, Cheng-Ju Yu, Chien-Fu Chen
Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan, Republic of China. · Department of Orthopedic Surgery, Spine Section and Bone and Joint Research Center, Chang Gung Memorial Hospital, Taoyuan, Taiwan, Republic of China.
Key points
From the paper's conclusion- This study develops a one-step TMB-amplified lateral flow immunoassay (osta-LFIA) by integrating Pd@Pt bimetallic nanoparticles with a 3D flow channel for quantitative detection of procollagen type I N-terminal propeptide (P1NP).
Abstract
Sensitive and rapid quantification of bone formation biomarkers is essential for therapeutic monitoring of osteoporosis. This study develops a one-step TMB-amplified lateral flow immunoassay (osta-LFIA) by integrating Pd@Pt bimetallic nanoparticles with a 3D flow channel for quantitative detection of procollagen type I N-terminal propeptide (P1NP). The Pd@Pt nanozyme exhibits excellent peroxidase-like activity and high substrate affinity, enabling efficient colorimetric signal amplification. The 3D flow channel enables controlled fluid transport and sequential release of pre-dried amplification reagents, simplifying operation, and enhancing reproducibility. Under optimized conditions, the osta-LFIA achieves a P1NP detection limit of 0.17 ng/mL, representing an approximately tenfold improvement over the non-amplified assay. Clinical validation using serum samples demonstrated agreement with the Elecsys total P1NP assay, confirming the accuracy and reliability of the platform. Interference studies using serum samples containing bilirubin, hemoglobin, and triglycerides at 10-fold their respective upper reference limits showed comparable responses to those obtained from serum without added interferents. This sensitive, rapid, low-cost, and portable platform enables quantitative monitoring of osteoporosis biomarkers for timely therapeutic assessment and point-of-care testing. By integrating catalytic signal amplification with automated reagent delivery, the system minimizes manual handling while maintaining analytical performance, making it suited for decentralized osteoporosis management in clinical settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Au/Pt@PEG Nanozymes Probe for Ultrasensitive and Matrix-Robust Lateral Flow Immunoassay of Cardiac Troponin I.Langmuir : the ACS journal of surfaces and colloids · 2026
- Polydopamine nanoparticle-based colorimetric-photothermal dual-mode lateral flow immunoassay for thromboembolism diagnosis.RSC advances · 2026
- Plasmon-Enhanced Fluorescence Lateral Flow Assay Using Silica-Spaced Ag@SiO2@RuBpy Nanoprobes for Ultrasensitive and Dual-Mode Procalcitonin Detection.Analytical chemistry · 2026
- Charge-mediated directed assembly of Pt nanoshell on PDA: colorimetric-catalytic co-enhanced lateral flow immunoassay for point-of-care testingJournal of Nanobiotechnology · 2025
- A Rational Optimization Approach for the Development of a Multiplexed Lateral Flow Immunoassay: Detection of Nonepithelial Ovarian Cancer Markers in Human SerumAdvanced Science · 2026
- Fondaparinux-Enabled Competitive Lateral Flow Assay for Monitoring Lactoferrin Bioactivity during Dairy ProcessingLangmuir · 2026