Charge-mediated directed assembly of Pt nanoshell on PDA: colorimetric-catalytic co-enhanced lateral flow immunoassay for point-of-care testing
Xingsheng Yang, Lei Ren, Jing Liang, Jiaojiao Gao, Chongwen Wang, Xiaoxian Liu, Xiaojing Wang, Rui Xiao
First Affiliated Hospital of Bengbu Medical College · United States Air Force
Key points
From the paper's conclusion- Based on these advantages, we further developed a LFIA for detecting the influenza A virus using PDA@Pt nanozyme, achieving direct colorimetric detection within 12 min and enhanced colorimetric results through a 2 min additional catalytic reaction that increased sensitivity by 100-fold.
Abstract
Effectively enhancing the detection sensitivity of lateral flow immunoassay (LFIA) without dependence on instruments has crucial implications for point-of-care diagnostics. Herein, we introduce a core-shell structured polydopamine (PDA)@platinum (Pt) nanozyme that boosts the colorimetric signal and amplifies the catalytic signal output of LFIA test strips, significantly enhancing the performance of visual detection. The synthesis of PDA@Pt employs a polyethyleneimine-mediated one-step reduction method, which simply controls the growth of Pt particles on the PDA surface, thereby forming a uniform Pt shell layer and providing enhanced chromatic catalytic synergistic effects. The newly developed PDA@Pt nanozyme exhibits dual functionality for visualization and catalytic enhancement, demonstrating favorable stability and reproducibility in complex samples, along with excellent flow characteristics within the LFIA system. Based on these advantages, we further developed a LFIA for detecting the influenza A virus using PDA@Pt nanozyme, achieving direct colorimetric detection within 12 min and enhanced colorimetric results through a 2 min additional catalytic reaction that increased sensitivity by 100-fold. The detection limits of PDA@Pt-LFIA in colorimetric and catalytic modes reached 0.5 and 0.005 ng/mL, which were 2 and 200 times lower than those of traditional AuNP-based LFIA, respectively. Furthermore, during testing with actual clinical samples, this technology exhibited 100% consistency with qPCR results, highlighting its considerable potential for practical pathogen detection.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Polydopamine nanoparticle-based colorimetric-photothermal dual-mode lateral flow immunoassay for thromboembolism diagnosis.RSC advances · 2026
- Development of a Lateral Flow Assays Sensing Platform Based on Aptamer-Modified Pt@Au Nanozymes for The Detection of KanamycinInternational Journal of Advanced Engineering and Technology Research · 2026
- From sensitivity challenges to nanozyme-driven signal amplification in lateral flow immunoassays for biomarker detection.Journal of pharmaceutical and biomedical analysis · 2026
- Au/Pt@PEG Nanozymes Probe for Ultrasensitive and Matrix-Robust Lateral Flow Immunoassay of Cardiac Troponin I.Langmuir : the ACS journal of surfaces and colloids · 2026
- Bacterial biomineralization-engineered Ag-Pt nanozyme for label-free and sensitive colorimetric detection of enrofloxacin in aquatic products.Analytical and bioanalytical chemistry · 2026
- Plasmon-Enhanced Fluorescence Lateral Flow Assay Using Silica-Spaced Ag@SiO2@RuBpy Nanoprobes for Ultrasensitive and Dual-Mode Procalcitonin Detection.Analytical chemistry · 2026