Small (Weinheim an der Bergstrasse, Germany)

A miRpair-Based Molecular Comparator for Lung Cancer Diagnosis.

Jiajia Song, Ruiting Liu, Linguo Gu, Kemin Wang, Zhenkun Xia, Qiuping Guo, Jin Huang

State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha, People's Republic of China. · Department of Thoracic Surgery, The Second Xiangya Hospital of Central South University, Changsha, People's Republic of China.

Key points

From the paper's conclusion
  • We subsequently translate the comparator into a DNA-based molecular workflow via asymmetric polymerase chain reaction (PCR) and polymerase-assisted hybridization subtraction (PAH-Sub).

Abstract

Early and precise cancer diagnosis is crucial for effective treatment. MicroRNAs (miRNAs) are promising diagnostic targets, but translating their complex, multi-dimensional expression signatures into clinical practice remains challenging. Here, we develop a concise molecular comparator using relative expression levels of specific miRNA pairs. The miRpair-based strategy demonstrates superior diagnostic performance compared to methods relying on the absolute quantification of single miRNAs. For non-small cell lung cancer (NSCLC) diagnosis, we identify hsa-miR-148a-3p/hsa-miR-30d-5p as the optimal diagnostic pair from The Cancer Genome Atlas (TCGA) data, with an area under the curve (AUC) of 0.975. The silicon-based model achieves 90.3% accuracy in 93 clinical serum samples using quantitative analysis. We subsequently translate the comparator into a DNA-based molecular workflow via asymmetric polymerase chain reaction (PCR) and polymerase-assisted hybridization subtraction (PAH-Sub). This process performs threshold-based comparison of dual-miRNA relative abundance directly at the molecular level. Integration with catalytic hairpin assembly (CHA) amplification generates fluorescent diagnostic outputs. Validation with 40 clinical serum samples yielded 87.5% accuracy, demonstrating the feasibility of molecular-level implementation of the miRpair decision rule. This study represents a proof-of-concept evaluation for NSCLC diagnosis. Further validation in independent cohorts incorporating clinically relevant disease controls will be required to establish broader clinical specificity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers