LNA-Modified Magnetic Bead Platform with Surface HCR for Streamlined Capture and Amplification of Serum miR-182 in Lung Cancer Diagnosis
Xiao Xiao, Huihao Ren, Yi Wang, Tongxin Yin, Qinwen Ba, Shaoran Xu, Yuting Feng, Jiawen Li,
Key points
From the paper's conclusion- Collectively, this platform shows potential as a non-invasive auxiliary diagnostic approach for serum miRNA detection.
Abstract
Accurate differentiation between malignant and benign pulmonary nodules remains a significant clinical challenge. MicroRNAs (miRNAs) are stably present in serum and exhibit early tumorigenic changes, making them ideal biomarkers for liquid biopsy-based cancer detection. However, as the classic method for miRNA detection, conventional reverse transcription-quantitative PCR (RT-qPCR) is limited by multi-step procedures, enzyme dependence, and reproducibility that can be affected by batch-to-batch enzyme variability. To address these limitations, we developed a platform integrating locked nucleic acid (LNA)-enhanced magnetic bead (MB) capture, on-bead hybridization chain reaction (HCR) amplification, and flow cytometric dual-parameter readout for the detection of serum miR-182, a marker for non-small cell lung cancer (NSCLC). By assembling the LNA-modified hairpin onto MBs, a simplified one-step detection of serum microRNA can be achieved, which triggers HCR amplification upon miR-182 recognition. The optimized assay achieved a detection limit of 0.48 pM with excellent specificity against 9 potentially interfering miRNAs. Compared to RT-qPCR (56 manual operation steps, 500 μL serum, area under the receiver operating characteristic curve (AUC) = 0.7887, 95% confidence interval (CI): 0.6680~0.9094), our method reduces the number of manual operation steps to 19 and requires just 1 μL of serum input, while achieving a favorable diagnostic AUC of 0.8140 in 61 clinical samples (31 lung cancer and 30 non-cancer controls, 95% CI: 0.7097~0.9183); these comparisons refer to manual steps and serum input volume, not to total assay time. This LNA-HCR-flow cytometry platform provides an operationally simplified approach for serum miRNA detection, with intra-day and inter-day CV values below 10% under the tested conditions. Collectively, this platform shows potential as a non-invasive auxiliary diagnostic approach for serum miRNA detection. However, the present study is an exploratory proof-of-concept, and the current cohort cannot yet establish clinical utility for the specific differential diagnosis of malignant versus benign pulmonary nodules.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fluorosphere-Assisted Nano-Biosensor for Detection of Circulating microRNAs in Non-Small Cell Lung CancerbioRxiv · 2026
- Ultrasensitive fluorescent biosensor for miRNA-34a detection: Magnetic separation coupled with cascade amplification of duplex-specific nuclease-assisted and hybridization chain reaction.Nanomedicine : nanotechnology, biology, and medicine · 2026
- Fusogenic Liposome-Mediated Extracellular Vesicles MicroRNA Profiling for Lung Cancer DiagnosisACS Nano · 2026
- Intelligent Modular Dual-Readout Architecture Driven by CRISPR/Cas13a-CHA Cascade and Machine Learning for Portable Multiplex MicroRNA Liquid Biopsy in Early Lung Cancer.ACS sensors · 2026
- An RNase domain-dependent microRNA detection with DNA-spiked nanocage for accurate cancer diagnosis.Nature communications · 2026
- The Yenos/MinION Multi-Cancer Early Detection Liquid Biopsy Test: An Innovative Approach to MicroRNA Quantification.Methods in molecular biology (Clifton, N.J.) · 2026