Respirology (Carlton, Vic.)

ROX Index for Prediction of 48-h Reintubation After Extubation in Medical ICU Patients Receiving High-Flow Nasal Cannula.

Junsu Choe, Byeong-Ho Jeong, Kyeongman Jeon

Division of Pulmonary and Critical Care Medicine, Department of Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea.

Observational

Key points

From the paper's conclusion
  • ROX demonstrated limited discriminative performance for predicting reintubation after extubation in patients receiving post-extubation HFNC. However, discrimination varied by hypoxaemia severity, and ROX may serve as an adjunct for post-extubation risk stratification in patients with PaO2/FiO2 < 200.

Abstract

BACKGROUND AND OBJECTIVE: The respiratory rate-oxygenation (ROX) index predicts HFNC failure in pneumonia with hypoxemic respiratory failure, but its utility in the post-extubation HFNC setting remains unclear. METHODS: We retrospectively analysed data from a prospectively enrolled observational ICU cohort at Samsung Medical Center (Seoul, Korea). Among 1881 mechanically ventilated adults, we analysed 726 extubation episodes managed with post-extubation HFNC. The primary outcome was reintubation within 48 h. ROX was calculated hourly for 24 h after extubation. Diagnostic discrimination was assessed using area under the receiver operating characteristic curve (AUROC) and clustered receiver operating characteristic methods, stratified by PaO2/FiO2 on the day of extubation. RESULTS: Reintubation occurred in 112/726 extubation episodes (15.4%). Overall, ROX demonstrated limited discrimination (AUROC 0.681 at 2 h, 0.681 at 6 h, 0.677 at 12 h, 0.730 at 18 h, and 0.614 at 24 h). Clustered AUROC varied according to hypoxaemia severity: 0.545 (PaO2/FiO2 ≥ 300; n = 118), 0.684 (PaO2/FiO2 200-< 300; n = 460), and 0.762 (PaO2/FiO2 < 200; n = 148). In PaO2/FiO2 < 200, even-hour-derived ROX thresholds performed similarly in odd hours: rule-in 4.21 and 6.60, balanced 9.70 (Youden), and rule-out 12.50 and 16.96. Median time from ROX < 9.7 to reintubation was 14.1 h. CONCLUSION: ROX demonstrated limited discriminative performance for predicting reintubation after extubation in patients receiving post-extubation HFNC. However, discrimination varied by hypoxaemia severity, and ROX may serve as an adjunct for post-extubation risk stratification in patients with PaO2/FiO2 < 200.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

ROX Index for Prediction of 48-h Reintubation After Extubation in Medical ICU Patients Receiving High-Flow Nasal Cannula — Science Skim