Test-Retest Reliability, Learning Effect and Measurement Error of the Modified Shuttle Test (MST) in Children With Asthma: A Multicenter Study.
Lara Bezerra Radis, Vitória Cavalheiro Puzzi, Thaila Corsi Dias, Natielly Soares Correia, Jéssica Lane Felippe Montes, Mariana Mazzuca Reimberg, Fernanda Cordoba Lanza, Evelim Leal de Freitas Dantas Gomes,
Associated Graduate Program (MSc and PhD) in Rehabilitation Sciences at State University of Londrina (UEL) and University Pitágoras UNOPAR (UNOPAR), Londrina, Paraná, Brazil. · University Nove de Julho, UNINOVE, São Paulo, São Paulo, Brazil.
Key points
From the paper's conclusion- The MST demonstrated excellent test-retest reliability and acceptable measurement error for assessing exercise capacity in children with asthma. Although a systematic difference was observed between tests, there was no evidence of a consistent learning effect, with individual variability in repeated performance.
Abstract
OBJECTIVE: To investigate test-retest reliability, measurement error (standard error of measurement [SEM] and minimum detectable difference [MDD]), and the learning effect of the Modified Shuttle Test (MST) in children with asthma. METHODS: Multicenter cross-sectional study including clinically stable children aged 6-12 years with asthma. Lung function and exercise capacity were assessed using MST. Intraclass Correlation Coefficient (ICC) was calculated to assess test-retest reliability. The first and second tests were compared using the paired Student's t-test to assess differences between tests. SEM and MDD were calculated to quantify measurement error. RESULTS: One hundred and twenty three children were included (71 boys [57%]; median age 9 [7-10] years). The mean distance covered in the best MST was 611 ± 214 meters (confidence interval [95% CI] = 573-649meters). The MST showed an excellent test-retest reliability (ICC = 0.96; 95% CI: 0.95-0.97). Distance was significantly lower in the second test than in the first (574 ± 218 vs. 601 ± 216 m; p = 0.0001). Learning effect was -27 ± 79 (4% ± 14%), the SEM was 56 meters (9.5%), and the MDD was 156 m (26.6%). CONCLUSION: The MST demonstrated excellent test-retest reliability and acceptable measurement error for assessing exercise capacity in children with asthma. Although a systematic difference was observed between tests, there was no evidence of a consistent learning effect, with individual variability in repeated performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- How many athletes are enough? Small-sample instability of reliability indices and the minimum sample size for a trustworthy minimal detectable change in two-trial sport field tests: a Monte Carlo study.BMC sports science, medicine & rehabilitation · 2026
- A Delphi-Based Item Set for Pre-Test Asthma Probability Assessment in Children Undergoing Methacholine Challenge Test.Pediatric pulmonology · 2026
- Exercise training program in children and adolescents with asthma: a randomized clinical trial.Revista paulista de pediatria : orgao oficial da Sociedade de Pediatria de Sao Paulo · 2026
- Reducing multiple-breath washout test burden in cystic fibrosis: agreement between the first acceptable trial and mean lung clearance index.Journal of cystic fibrosis : official journal of the European Cystic Fibrosis Society · 2026
- Sufficient Standardization? Evaluating the Reliability of an Inertial Sensor (BeyondTM) for Ankle Dorsiflexion After a Brief Familiarization PeriodSports · 2025
- Impulse oscillometry reference values and small airway reversibility in the assessment of asthma.Annals of allergy, asthma & immunology : official publication of the American College of Allergy, Asthma, & Immunology · 2026