Real-Time Measurement of Particulate Concentration: Laser Surgery With Jet Ventilation.

S Syam, Justin Jou, Bryan E Schmidt, N Scott Howard

Mechanical and Aerospace Engineering Case Western Reserve University Cleveland Ohio USA. · School of Medicine, Otolaryngology, Head and Neck Surgery University Hospitals, Cleveland Medical Center Ohio USA.

Key points

From the paper's conclusion
  • We recommend using one or two suction devices and high‐filtration masks during jet ventilation‐assisted laser procedures to minimize the risk posed by the aerosols generated during these procedures.

Abstract

OBJECTIVE: To quantify the particulate concentration in exhalation plumes during laser surgery procedures under jet ventilation and to examine the effect of mitigation strategies via suction. STUDY DESIGN: In vivo quantitative study. SETTING: Tertiary care operating room. METHODS: The particulate concentration in the jet ventilation plume was measured in real-time using an optical particle sizer. Several suction configurations were tested to evaluate their effects on the particle concentrations in the plume. RESULTS: The total particle concentration increased significantly during CO2 laser use with simultaneous jet ventilation. The sustained post-procedure total concentration was on average 27% higher than the pre-procedure level. With the application of two sources of suction, total concentrations of small, medium, and larger particles in the exhalation plume during CO2 laser ablation were reduced by 54%, 85%, and 89%, respectively, compared to no suction. During the recovery phase, the reductions were 97%, 94%, and 84%, respectively. Although suction reduced the concentration of all particle sizes in the plume, the concentration of submicron particles remained high. CONCLUSION: Suction significantly reduced particle concentration in the plume during laser ablation compared to the appreciable levels produced with no suction; the two-suction use case was found to be most effective. However, the elimination of submicron particulates in the plume by suction devices was found to be less efficient. We recommend using one or two suction devices and high-filtration masks during jet ventilation-assisted laser procedures to minimize the risk posed by the aerosols generated during these procedures. Further mitigation studies are warranted.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Real-Time Measurement of Particulate Concentration: Laser Surgery With Jet Ventilation — Science Skim