Decoupling Surgical Bioaerosol Burden and Biological Activity with Point-of-Care Microfluidic-Plasmonic Biosensing.
Yirou Liang, Jizhuang Luo, Danhua Wang, Yunbo Li, Bangchao Xi, Pengxin Huang, Jiayun Wu, Linlin Liu,
Institute of Medical Robotics, School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai200240, P.R. China. · Department of Thoracic Surgery, Shanghai Chest Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai200003, P.R. China.
Key points
From the paper's conclusion- Here, we present Surgical Personalized On-site Tracker (SPOT), a portable microfluidic sampling-to-biosensing system with localized surface plasmon resonance (LSPR) biosensing for dual-parameter assessments of proteinaceous aerosol burden and accessible adenosine triphosphate (ATP).
Abstract
Point-of-care bioaerosol analysis remains a critical gap in perioperative exposure assessment, as existing air-monitoring approaches primarily quantify particle burden while providing limited information on aerosol-associated biomolecular composition. Here, we present Surgical Personalized On-site Tracker (SPOT), a portable microfluidic sampling-to-biosensing system with localized surface plasmon resonance (LSPR) biosensing for dual-parameter assessments of proteinaceous aerosol burden and accessible adenosine triphosphate (ATP). The SPOT platform enables on-site detection of total protein as a surrogate for aerosolized biological loads, whereas the ATP channel quantifies accessible ATP after aerosol collection and sample processing without intentional cell lysis. In a clinical study conducted during thoracic surgeries, SPOT detected markedly elevated bioaerosols compared with nonsurgical conditions, with total proteinaceous bioaerosol burden levels reaching 39.93 pg/m3 and accessible ATP concentrations up to 78.97 pmol/m3. Importantly, minimally invasive procedures exhibited a significantly higher ATP-to-protein ratio than open surgeries, i.e., 3.15 vs 2.07 pmol/pg, revealing disproportionally elevated accessible ATP within surgical plumes despite lower total mass. These findings established ATP-to-protein profiling as a novel metric for functional bioaerosol surveillance and demonstrated the potential of SPOT for perioperative air-quality monitoring and biosafety evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Developing a sensitive indoor air surveillance approach for nosocomial pathogens and antimicrobial resistancebioRxiv · 2026
- A Microfluidic Colorimetric Biosensor Integrated with Water-Soluble Nonwoven Fabrics for Collection and Detection of Bacterial AerosolsAnalytical Chemistry · 2025
- Size Amplification Sensing of Bacteria Encapsulated by Polymer Colloids for Achieving Total and Specific Particle CountingAnalytical Chemistry · 2026
- Evaluation of Two Cyclonic Bioaerosol Samplers for Hospital Air Monitoring in a Calibrated Test Chamber Integrating Aerodynamics and Biological EndpointsIndoor Air · 2026
- MetaboSense: An Integrated Quantum Dot-Mediated Aptamer Assay and Modular Microfluidic Platform for Continuous In-Line Monitoring of Lung Metabolism During Ex Vivo Perfusion.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- High-Sensitivity Molecular Detection of Viral Bioaerosols Using a Composite Collection System and Optimized RPA-CRISPR/Cas12a.Analytical chemistry · 2026