Effect of Steady Flow Amplitude on Hemodynamics at Transverse-Sigmoid Sinus Junction in Pulsatile Tinnitus.
Ben Liu, Fanrui Yu, Yicheng Han, Lihui Zhuang, Xiaoyu Qiu, Heyu Ding, Shusheng Gong, Guopeng Wang,
Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, China. · Department of Radiology, Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Key points
From the paper's conclusion- This study identifies steady flow amplitude as a vital hemodynamic regulator at the TS-SS junction, providing novel quantitative evidence to clarify PT pathophysiological mechanisms. Modulating steady flow amplitude may improve abnormal hemodynamic on the SSWD region, offering a potential targeted therapeutic strategy for PT patients.
Abstract
OBJECTIVE: Pulsatile tinnitus (PT) induced by sigmoid sinus wall dehiscence (SSWD) combined with diverticulum severely reduces patients' quality of life. Hemodynamic disturbances at the transverse-sigmoid sinus (TS-SS) junction exert crucial pathogenic effects on PT. However, the influence of steady flow amplitude remains unclear. This study aimed to investigate the effect of changes in steady flow amplitude on hemodynamic parameters at the TS-SS junction in PT patients. STUDY DESIGN: Case series. SETTING: Tertiary Academic Center. METHODS: Patient-specific venous models of three PT patients were reconstructed from clinical imaging. Nine flow conditions were established: baseline and steady flow amplitude adjustments of ±20%, ±40%, ±60%, and ±80%. Transient computational fluid dynamics was used to quantify blood flow patterns, wall pressure, and wall shear stress (WSS) at the TS-SS junction. RESULTS: Reduced steady flow amplitude attenuated flow disturbance on the SSWD region, shrank high-pressure and high-WSS zones, and reduced average/maximum pressure ( P avg , P max ) and average/maximum WSS ( WSS avg , WSS max ) in this area. Conversely, increased steady flow amplitude aggravated flow disturbance, expanded high-pressure and high-WSS regions, and elevated all the above hemodynamic parameters. Statistical analysis revealed a significant quadratic relationship between steady flow amplitude and P avg , P max , WSS avg , and WSS max (R2 > 0.999, P < .0001). CONCLUSION: This study identifies steady flow amplitude as a vital hemodynamic regulator at the TS-SS junction, providing novel quantitative evidence to clarify PT pathophysiological mechanisms. Modulating steady flow amplitude may improve abnormal hemodynamic on the SSWD region, offering a potential targeted therapeutic strategy for PT patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Pulsatile Tinnitus: Diagnostic Evaluation, Otologic Management, and When to Refer.Otolaryngologic clinics of North America · 2026
- Sigmoid Sinus Wall Reconstruction for Venous Pulsatile Tinnitus: A Critical Review of Surgical Outcomes, Hemodynamic Evidence, and Pressure-Associated Findings.Audiology research · 2026
- Surgical treatment of pulsatile tinnitus arising from sigmoid sinus wall anomalies.Journal of the Chinese Medical Association : JCMA · 2026
- Not All Transverse Sinus Stenoses Behave the Same: Distinct Flow Phenotypes on Phase-Contrast MRI.Cureus · 2026
- Assessment of Transverse-sigmoid Sinus Dural Arteriovenous Fistula using Transcranial Doppler Ultrasonography: A Case Report.Current medical imaging · 2026
- Transverse sinus dominance predicts outcome after venous sinus stenting for pulsatile tinnitus.European radiology · 2026