Not All Transverse Sinus Stenoses Behave the Same: Distinct Flow Phenotypes on Phase-Contrast MRI.
Erick D Villarreal-Ibañez, Juan C Mantilla-Suarez, Federico G Lubinus-Badillo, C Alejandro Luzardo-Neira, Juan C Uribe-Caputti, Daniel E Mantilla-Garcia
Radiology, Fundación Oftalmológica de Santander - FOSCAL, Bucaramanga, COL. · Epidemiology and Public Health, Universidad Autónoma de Bucaramanga, Bucaramanga, COL.
Key points
From the paper's conclusion- This study evaluated peak velocity changes across transverse sinus stenoses using phase-contrast magnetic resonance imaging (MRI) and explored whether distinct hemodynamic patterns could be identified.
Abstract
Background Transverse sinus stenosis is usually assessed by its anatomical appearance, although stenoses with similar morphology may not have the same local flow behavior. This study evaluated peak velocity changes across transverse sinus stenoses using phase-contrast magnetic resonance imaging (MRI) and explored whether distinct hemodynamic patterns could be identified. Methods We retrospectively reviewed 183 consecutive patients who underwent brain MRI, magnetic resonance venography, and venous phase-contrast MRI for headache, vertigo, and/or tinnitus between September 2025 and June 2026. Transverse sinus stenosis was identified in 14 patients, including four with bilateral stenosis, yielding 18 stenotic segments. Peak velocity was measured immediately proximal to the stenosis, at the point of greatest narrowing, and immediately distal to it. Each segment was classified as Jet when intra-stenotic velocity exceeded both adjacent measurements, Low-flow when it was lower than both, or Intermediate when neither criterion was met. Results The mean age of the 14 patients was 50.7 ± 10.1 years, 11 (78.6%) were women, and the mean body mass index was 27.4 ± 3.5 kg/m². Headache was present in 10 patients (71.4%), vertigo in five (35.7%), and tinnitus in two (14.3%). Across all stenotic segments, mean peak velocity was 16.97 cm/s before the stenosis, 12.84 cm/s within it, and 14.82 cm/s after it. Seven segments (38.9%) showed a Jet pattern, with mean velocities of 14.26, 18.49, and 11.43 cm/s, respectively. Ten segments (55.6%) showed a Low-flow pattern, with corresponding velocities of 19.00, 8.92, and 18.14 cm/s. One segment (5.6%) had an Intermediate pattern. Five patients (35.7%) had three or more imaging findings suggestive of idiopathic intracranial hypertension. Conclusions Transverse sinus stenoses showed heterogeneous local flow behavior on phase-contrast MRI. Reduced intra-stenotic velocity was more common than the expected acceleration pattern, suggesting that anatomical narrowing does not represent a single hemodynamic entity. These preliminary phenotypes require validation against stenosis morphology, venous manometry, and clinical outcomes before their clinical relevance can be established.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transverse sinus dominance predicts outcome after venous sinus stenting for pulsatile tinnitus.European radiology · 2026
- Hemodynamic unmasking of serial cerebral venous sinus stenoses following treatment of the rate-limiting lesion.Journal of neurointerventional surgery · 2026
- Regional Perivascular Space Burden in Pediatric Idiopathic Intracranial Hypertension: A Case-Control MRI Study.Diagnostics (Basel, Switzerland) · 2026
- Biomechanical study of intracranial arterial stenosis based on fractional fluid–structure interactionPhysics of Fluids · 2026
- Multimodal evaluation and etiology-oriented management of chronic intracranial venous hypertension.Frontiers in neurology · 2026
- Papilledema is not the point: intracranial pressure dysregulation as a common pathway in migraine and idiopathic intracranial hypertension.Brain communications · 2026