Magnetic resonance in medicine

Real-Time Correction of Respiration-Induced B 0 Changes in Oscillating Steady State Imaging (OSSI) fMRI.

Mariama Salifu, Kang Wang, Sherry Huang, Douglas C Noll

Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA. · GE HealthCare, Waukesha, Wisconsin, USA.

Key points

From the paper's conclusion
  • This approach is effective in reducing B 0 -induced signal changes, allowing realization of theoretical SNR gains in complex steady-state MRI sequences, particularly in cases affected by respiratory motion.

Abstract

PURPOSE: Oscillating steady-state imaging (OSSI) is an fMRI acquisition technique that utilizes a novel oscillating steady-state by combining balanced gradients and quadratic RF phase cycle to achieve a higher SNR compared to spoiled GRE. Despite its SNR advantage, OSSI is sensitive to fluctuations in the B 0 field due to respiration and drift, which limits the achievable SNR gains. These fluctuations cause shifts in the resonant frequency, disrupting the magnetic steady-state and the functional contrasts. This study proposes a robust zeroth-order prospective correction for multi-shot OSSI fMRI. METHODS: FIDNavs were inserted into a 2D OSSI sequence for real-time processing to track respiration- and drift-induced B 0 fluctuations during both low-resolution (3-shot) and high-resolution (6-shot) acquisitions. These fluctuations were estimated on a per-shot basis while accounting for shot-dependent phase variations introduced by eddy currents. The resulting B 0 estimates were then used to dynamically adjust the excitation and receiver phase progressions. RESULTS: Real-time tracking and correction led to substantial improvements in functional sensitivity and signal stability under both regular and deep breathing conditions. In the 3-shot acquisition, tSNR increased by up to 46.8% and activation volume by up to 411.1%, while the 6-shot acquisition exhibited more modest but consistent gains, with tSNR increases of up to 17.2%. Voxel-level time series demonstrated marked suppression of respiration-related oscillations, revealing more stable task-related modulation. CONCLUSION: This approach is effective in reducing B 0 -induced signal changes, allowing realization of theoretical SNR gains in complex steady-state MRI sequences, particularly in cases affected by respiratory motion.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Real-Time Correction of Respiration-Induced B 0 Changes in Oscillating Steady State Imaging (OSSI) fMRI — Science Skim