Key points
From the paper's conclusion- This approach is effective in reducing B 0 -induced signal changes, allowing realization of theoretical SNR gains in complex steady-state MRI sequences, particularly in cases affected by respiratory motion.
Abstract
PURPOSE: Oscillating steady-state imaging (OSSI) is an fMRI acquisition technique that utilizes a novel oscillating steady-state by combining balanced gradients and quadratic RF phase cycle to achieve a higher SNR compared to spoiled GRE. Despite its SNR advantage, OSSI is sensitive to fluctuations in the B 0 field due to respiration and drift, which limits the achievable SNR gains. These fluctuations cause shifts in the resonant frequency, disrupting the magnetic steady-state and the functional contrasts. This study proposes a robust zeroth-order prospective correction for multi-shot OSSI fMRI. METHODS: FIDNavs were inserted into a 2D OSSI sequence for real-time processing to track respiration- and drift-induced B 0 fluctuations during both low-resolution (3-shot) and high-resolution (6-shot) acquisitions. These fluctuations were estimated on a per-shot basis while accounting for shot-dependent phase variations introduced by eddy currents. The resulting B 0 estimates were then used to dynamically adjust the excitation and receiver phase progressions. RESULTS: Real-time tracking and correction led to substantial improvements in functional sensitivity and signal stability under both regular and deep breathing conditions. In the 3-shot acquisition, tSNR increased by up to 46.8% and activation volume by up to 411.1%, while the 6-shot acquisition exhibited more modest but consistent gains, with tSNR increases of up to 17.2%. Voxel-level time series demonstrated marked suppression of respiration-related oscillations, revealing more stable task-related modulation. CONCLUSION: This approach is effective in reducing B 0 -induced signal changes, allowing realization of theoretical SNR gains in complex steady-state MRI sequences, particularly in cases affected by respiratory motion.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Self-Correction of B0 Drift and Trajectory Error in Alternating Unbalanced SSFP-FID and SSFP-ECHO (AUSFIDE)-Based 3D Transverse Relaxometry of the Human Brain.Magnetic resonance in medicine · 2026
- Respiratory rate estimation by using realignment data from a 1-minute high-temporal-resolution MRI sequence: A feasibility study.Acta radiologica (Stockholm, Sweden : 1987) · 2026
- Robust State-space Reconstruction of Brain Dynamics via Bootstrap Monte Carlo SSA.ArXiv · 2026
- SORDINO: silent, sensitive, specific and artifact-resistant fMRI in awake, behaving mice.Nature neuroscience · 2026
- Servo Navigation and Phase Equalization Enhanced by Run-Time Stabilization (PEERS) for 3D EPI Time Series.Magnetic resonance in medicine · 2026
- Improved Accuracy of Multidimensional Spatially-Selective Saturation RF Pulses for Short-Repetition-Time Steady-State Imaging.Magnetic resonance in medicine · 2026