Feasibility of Singular Value Decomposition Implementation for 129Xe Hyperpolarized Chemical Exchange Saturation Transfer (HyperCEST) Molecular Imaging.
Yurii Shepelytskyi, Viktoriia Batarchuk, Guillem Dayer, Carson L Hasselbrink, Mitchell S Albert
Department of Chemistry, Lakehead University, Thunder Bay, Ontario, Canada. · Thunder Bay Regional Health Research Institute, Thunder Bay, Ontario, Canada.
Key points
From the paper's conclusion- Implementation of the proposed SVD-based method is beneficial for 129Xe HyperCEST molecular imaging due to significantly improved quantification of the HyperCEST effect, reduced variability of the localized HyperCEST values, and significantly improved quality of the HyperCEST depletion spectra.
Abstract
PURPOSE: To develop a method for enhanced quantification of hyperpolarized chemical exchange saturation transfer (HyperCEST) using singular value decomposition (SVD) for both spectroscopy and molecular imaging. METHODS: Dynamic HyperCEST spectra acquired with cucurbit[6]uril (CB[6]) and resorcinarene trimer methanesulfonate (R3-Noria-MeSO3H) in aqueous solution were subjected to SVD to denoise the magnetic resonance spectra. The HyperCEST depletion spectra were recalculated from SVD-reconstructed data using a standard approach. The on- and off-resonance coronal 129Xe images acquired from R3-Noria-MeSO3H samples in vitro and from three healthy rats post CB[6] injection were also reconstructed using SVD prior to pixel-by-pixel HyperCEST map calculation. A localized variance of the HyperCEST values was calculated. RESULTS: A paired t-test demonstrated a statistically significant increase (up to ∼13%) in localized HyperCEST values both in vivo (in the animal kidneys and aorta) and in vitro (across the phantom volume) due to the SVD incorporation. In addition, SVD significantly reduced HyperCEST variance. The HyperCEST variance for in vivo images was reduced by 32.3%, whereas the variance for in vitro images was reduced by 36%. The SNR of the SVD-reconstructed images and spectra was significantly higher. The SVD resulted in a significant improvement of the shape of HyperCEST depletion spectra and maximized the HyperCEST effect in the case of CB[6] for lower depolarization angles. CONCLUSION: Implementation of the proposed SVD-based method is beneficial for 129Xe HyperCEST molecular imaging due to significantly improved quantification of the HyperCEST effect, reduced variability of the localized HyperCEST values, and significantly improved quality of the HyperCEST depletion spectra.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robust spectral averaging and chemical shift calculation for hyperpolarized 129Xe MR spectroscopy.Magnetic resonance imaging · 2026
- Highly Sensitive Hyperpolarized Multiplexed Single-Scan 2D 13C-1H NMR of Complex Mixtures at Natural 13C Abundance.Analytical chemistry · 2026
- EXPRESS: Enhanced SVD for Signal-Noise Separation in Spectroscopic Data.Applied spectroscopy · 2026
- Evaluations of retrospective frequency and phase correction methods for single-voxel MR spectroscopy at 7T.bioRxiv : the preprint server for biology · 2026
- Quantitative Chemical Exchange Saturation Transfer Imaging With Golden‐Angle Radial k‐Space Sampling and Locally Low‐Rank ReconstructionNMR in Biomedicine · 2026
- Multi‑stage singular value decomposition for ultrafast ultrasound imaging of microbubbles.Ultrasonics · 2026