Enhancing the Motion Robustness of Breath-Held 3D T1-Weighted Abdominal MRI Using a Cartesian Acquisition With Spiral Profile Ordering.
Alice Scudeletti, Jonathan Stelter, Kilian Weiss, Lisa Steinhelfer, Robert L Walter, Rickmer F Braren, Dimitrios C Karampinos
Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany. · Philips GmbH Market DACH, Hamburg, Germany.
Key points
From the paper's conclusion- This study introduces a novel self-gated CASPR-based framework for respiratory motion compensation in 3D abdominal MRI, in cases of incomplete and delayed breath-holds. The method enables the extraction of the self-navigator signal along the anterior-to-posterior axis and compensates for motion using a soft-gating technique.
Abstract
PURPOSE: To develop and validate a novel self-gated motion-robust 3D T1-weighted gradient echo imaging framework based on a Cartesian acquisition with spiral profile ordering (CASPR) for abdominal imaging under unstable breath-hold conditions. METHODS: The CASPR trajectory was evaluated using frequency encoding in the anterior-to-posterior (AP) direction for respiratory motion robustness. The CASPR's intrinsic k-space center oversampling was exploited to directly extract a self-gated respiratory signal from the acquired data. A soft-gating motion compensation framework was integrated into the reconstruction pipeline. The method was validated in 10 healthy volunteers (five males and five females) and compared to a Cartesian acquisition with pseudorandom undersampling. RESULTS: Both CASPR and Cartesian acquisition with pseudorandom undersampling exhibited motion artifacts under unstable breath-hold conditions without retrospective correction. The proposed self-gated CASPR framework enabled reliable extraction of the respiratory signal directly from the AP readout. Soft gating significantly improved the image quality of motion-corrupted scans. CONCLUSION: This study introduces a novel self-gated CASPR-based framework for respiratory motion compensation in 3D abdominal MRI, in cases of incomplete and delayed breath-holds. The method enables the extraction of the self-navigator signal along the anterior-to-posterior axis and compensates for motion using a soft-gating technique.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DoReMe: Dual optimization of Reconstruction and Motion estimation for self-navigated free-breathing abdominal MRI using Gaussian SplattingarXiv · 2026
- GRACE ‐ MORE : A Motion‐Resolved Golden‐Angle Radial CEST MRI Technique for Free‐Breathing Abdominal ImagingMagnetic Resonance in Medicine · 2026
- Motion-robust high-resolution 3D-GRASE pseudo-continuous ASL perfusion imaging at 3TmedRxiv · 2026
- A self-navigated framework for motion detection and spoke-reordering musculoskeletal dynamic reconstruction in 3D radial MRI.Medical image analysis · 2026
- Rigid Motion Estimation Using Accelerated Coordinate Descent (REACT) for MR Imaging.Magnetic resonance in medicine · 2026
- Motion Mitigation Techniques for Abdominal and Cardiac MR ImagingJournal of Magnetic Resonance Imaging · 2025