Dual-Tuned 31P-1H Dual-Row Loop/Dipole 32-Element Transceiver Array for Human Brain Spectroscopy at 9.4T.
G A Solomakha, R Pohmann, F Glang, S Mueller, P I Valsala, T Platt, S Orzada, M E Ladd,
High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tuebingen, Germany. · Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
Key points
From the paper's conclusion- As a proof of concept, we developed the 32-element DT UHF tight-fit TxRx human head array coil for 31P MRS(I) with good 1H performance using a combination of loops and dipoles. The proposed array design could also be adapted to higher fields, that is, 10.5T, 11.7T, and 14T.
Abstract
PURPOSE: The goal of this work is to develop and evaluate a single-layer tight-fit 32-element dual-tuned (DT) loop/dipole transceiver (TxRx) array for human brain 31P MRS(I) at 9.4T, achieving full-brain coverage and reasonable transmit and receive performance at both frequencies. METHODS: First, we developed numerical models of dual-row TxRx arrays for 31P (loop array) and 1H (coaxial-end folded-end dipole array) frequencies at 9.4T. Next, multi-tissue voxel models were used to simulate Tx-performance of the arrays and define the optimal CP-mode excitation. Following this, the proposed array's performance was evaluated by MR measurements both on a phantom and a healthy volunteer. Finally, we compared the proposed array to the previously reported DT single-row loop-based TxRx array. RESULTS: The developed 32-element DT TxRx array demonstrated full-brain (including the cerebellum and brain stem) imaging capabilities, reasonable SNR, and transmit performance at both frequencies at 9.4T. CONCLUSION: As a proof of concept, we developed the 32-element DT UHF tight-fit TxRx human head array coil for 31P MRS(I) with good 1H performance using a combination of loops and dipoles. The proposed array design could also be adapted to higher fields, that is, 10.5T, 11.7T, and 14T.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design of an 8‐Channel Transmit 32‐Channel Receive 11.7T Head Coil and Evaluation of SNR GainsMagnetic Resonance in Medicine · 2026
- Evaluation of 7 Tesla pTx Body Coils Regarding Transmit and Receive Performance.Magnetic resonance in medicine · 2026
- Optimization of a Locally Shielded 16-Channel Transmit Array for Human Brain MRI at 10.5 T via Electromagnetic/Circuit Co-Simulation and Parallel Transmission StrategiesarXiv · 2026
- High Dynamic Range Turbo-FLASH B1 Mapping for Characterizing Multi-Transmit Multi-Receive RF Arrays, Validated at 7 T and 11.7 T.Magnetic resonance in medicine · 2026
- Detailed Consideration of a Novel Meandered Dipole Array for Magnetic Resonance Imaging of the Head at 3 Tesla with Low Radiofrequency Power DepositionSensors · 2026
- Combined Metasurface and Metamaterial Passive Transmit Lens and Receive Array for 3 T.Magnetic resonance in medicine · 2026