An Adaptive Metasurface for Adjustable Magnetic Resonance Imaging Enhancement at 3 T and 7 T: A Feasibility Study.
Paul S Jacobs, Pradnya Narvekar, Neil E Wilson, Gabor Mizsei, Wyger Brink, John A Detre, Mark A Elliott, Ravinder Reddy
Department of Radiology, Center for Advanced Metabolic Imaging in Precision Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. · Department of Radiology, The Metabolic Discovery Center at Penn, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Key points
From the paper's conclusion- This work establishes the feasibility of an adaptive, low-power metasurface for remote subject-specific image enhancement. While the current enhancement was limited by the prototype's small size and capacitance range, the design provides a scalable foundation for future design iterations adaptable across different field strengths and potentially for multiple nuclei.
Abstract
PURPOSE: Ultra-high field (≥ 7 T) and 3 T MRI suffer from B1 + inhomogeneity and signal loss. Conventional metasurfaces that mitigate B1 + inhomogeneity and improve image SNR are "fixed" in nature and designed for a single Larmor frequency. This study demonstrates the feasibility of an adaptive metasurface utilizing voltage-controlled capacitors to dynamically adjust electromagnetic properties for adjustable image enhancement at both 3 T and 7 T 1H Larmor frequencies. METHODS: A 3 × 3 unit-cell prototype was developed using voltage adjustable capacitors (33.0-16.5 pF) controlled by a 0-3 V DC source. Bench characterization and numerical simulations were performed to evaluate frequency characteristics and B1 + distributions. Empirical data was acquired via GRE imaging and B1 + mapping on 3 T and 7 T scanners. Multiple devices were also evaluated in tandem at 7 T to assess interference and spatial degrees of freedom. RESULTS: Simulations and phantom imaging confirmed voltage-dependent behavior. At 7 T, decreasing capacitance to 16.5 pF (3 V) yielded a 4.30× local SNR increase and a 60.0% boost in transmit efficiency. At 3 T, maximum enhancement (1.65× local SNR) occurred at 33.0 pF (0 V), demonstrating the ability of the device to adjust the optimal impedance between 128 and 300 MHz. Multiple metasurfaces successfully operated simultaneously without mutual interference, enabling multiregion enhancement. CONCLUSION: This work establishes the feasibility of an adaptive, low-power metasurface for remote subject-specific image enhancement. While the current enhancement was limited by the prototype's small size and capacitance range, the design provides a scalable foundation for future design iterations adaptable across different field strengths and potentially for multiple nuclei.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Combined Metasurface and Metamaterial Passive Transmit Lens and Receive Array for 3 T.Magnetic resonance in medicine · 2026
- Modular Metamaterials for Adaptable MRI Signal Control: Combining Dipole Array With a New Hexagon-Based Artificial Dielectrics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Nonlinear Curved Metasurfaces for Enhanced Thyroid Magnetic Resonance Imaging.ACS applied materials & interfaces · 2026
- A High-Performance Conformal Metamaterial for 1.5 T Wrist Magnetic Resonance Imaging.ACS applied materials & interfaces · 2026
- Optimization of a Locally Shielded 16-Channel Transmit Array for Human Brain MRI at 10.5 T via Electromagnetic/Circuit Co-Simulation and Parallel Transmission StrategiesarXiv · 2026
- High Dynamic Range Turbo-FLASH B1 Mapping for Characterizing Multi-Transmit Multi-Receive RF Arrays, Validated at 7 T and 11.7 T.Magnetic resonance in medicine · 2026