Optimal-Control 19F PROJECT Improves the Reliability of CPMG-Derived Relaxation Rates.
Marco Schiavina, Enrico Luchinat, Enrico Ravera
Department of Chemistry "Ugo Schiff", University of Florence, Sesto Fiorentino, Italy.
Key points
From the paper's conclusion- We benchmarked the J-compensated variant proposed by Aguilar et al. ("PROJECT"), implemented with seedless optimal-control (OC) shaped pulses specifically designed for covering more than 30 ppm at 659 MHz 19F Larmor frequency (16.4 T), directly against CPMG performed with the same OC shaped pulses.
Abstract
In fluorine-based fragment screening, protein-ligand interactions are monitored through the impact of binding on 19F NMR relaxation properties. Most often, filters based on transverse relaxation are applied, whereas some protocols foresee the measurement of relaxation constants to rank different hits. The largest contribution to relaxation, even at the most common fields used in biomolecular NMR, is chemical shielding anisotropy, proportional to the reorientation correlation time and to the square of the magnetic field. R2 values are thus usually measured using CPMG-type echo trains to mitigate exchange effects. When the observed 19F spin is scalarly coupled to another 19F spin, the CPMG refocusing train imposes a coherent J-modulation on the echo train, biasing the extracted R2. We benchmarked the J-compensated variant proposed by Aguilar et al. ("PROJECT"), implemented with seedless optimal-control (OC) shaped pulses specifically designed for covering more than 30 ppm at 659 MHz 19F Larmor frequency (16.4 T), directly against CPMG performed with the same OC shaped pulses. The comparison is performed on two model proteins across multiple sample conditions and two spin echo times. In this application note, we show that seedless-PROJECT recovers R2 estimates that are systematically more consistent with a J-free reference than a naive CPMG analysis-indistinguishable from CPMG when the coupling is negligible, and significantly better fit when it is resolved-at the price of a modest reduction in SNR. We outline a reusable protocol for other laboratories and provide a practical signal-to-noise ratio (SNR) threshold below which neither method returns reliable rates.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Parallelized 61-Sample Inhibition Screening Accelerated by 19F-MRI Compressed Sensing.Small methods · 2026
- Photo-CIDNP-Enhanced 19F NMR for Rapid Protein Conformation and Ligand Binding Analysis.Journal of the American Chemical Society · 2026
- 15N CPMG relaxation dispersion experiments for investigating μs-ms timescale dynamics of biomolecules with reduced sample heating effects.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2026
- Unraveling chemical exchanges through steady state free precession NMR.The Journal of chemical physics · 2026
- Solid-state NMR dipolar recoupling in the presence of large chemical shielding anisotropies by quaternion-based effective Hamiltonian optimal control.Physical chemistry chemical physics : PCCP · 2026
- Advancing oxygen-enhanced MRI acquisition and modelling through dynamic ${\Delta}R_{1}$ and ${\Delta}R_2^*$ sensingarXiv · 2026