Microwave and Optical Technology Letters

Closed‐loop Pole Stability Criterion and Quantitative Stability Analysis for High‐Order Charge‐Pump Phase‐Locked Loops

Zengshuang Wang, Yiting Zhang, Nengxu Zhu, Zenglong Zhao, Keping Wang, Fanyi Meng

Key points

From the paper's conclusion
  • It is applicable to charge‐pump PLLs using second‐ through fifth‐order active or passive loop filters and provides explicit quantitative constraints for the loop‐parameter design of RF frequency sources and high‐speed clock circuits.

Abstract

Open‐loop phase‐margin analysis is widely used to assess the stability of phase‐locked loops (PLLs). However, it characterizes only the open‐loop frequency response and cannot quantitatively relate closed‐loop pole locations to transient dynamics, damping, and resonant peaking, which limits quantitative stability‐margin evaluation for high‐order charge‐pump PLLs. Based on a linear small‐signal model and root‐locus theory, this work derives the closed‐loop pole‐zero distributions of second‐ through fifth‐order charge‐pump PLLs and establishes a quantitative closed‐loop pole constraint for practical stability‐margin evaluation: excluding pole‐zero doublets, the magnitude of the real part of every pole of the closed‐loop transfer function should be greater than one‐half of the loop bandwidth. Used together with conventional Bode‐plot phase‐margin analysis, the proposed criterion enables complementary stability verification in the open‐loop frequency domain and the closed‐loop complex‐frequency domain. A 6 GHz fifth‐order PLL frequency source using an active loop filter is evaluated through circuit simulation and three‐temperature environmental testing of a 9 × 9 mm microassembled prototype. When the dominant closed‐loop poles violate the proposed criterion, the PLL loses lock and drifts toward lower frequencies even though the open‐loop phase margin is 45°. After the loop‐filter parameters are optimized so that the relevant poles satisfy the criterion, the PLL remains stably locked over the full temperature range and achieves a measured phase noise of −109 dBc/Hz at a 100 kHz offset. The analytical, simulated, and measured results consistently validate the criterion. It is applicable to charge‐pump PLLs using second‐ through fifth‐order active or passive loop filters and provides explicit quantitative constraints for the loop‐parameter design of RF frequency sources and high‐speed clock circuits.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Closed‐loop Pole Stability Criterion and Quantitative Stability Analysis for High‐Order Charge‐Pump Phase‐Locked Loops — Science Skim