The Role of Cochlear Anatomy in Hearing Preservation After Cochlear Implantation in Adults: A Systematic Review.
Bo Uzeel, Freya Swinnen, Veroniek Van Driessche, Dorien Ceuleers, Ingeborg Dhooge
Department of Otorhinolaryngology Ghent University Hospital Ghent Belgium. · Department of Diagnostic Sciences Ghent University Ghent Belgium.
Key points
From the paper's conclusion- Cochlear anatomy may influence hearing preservation following cochlear implantation, with longer cochlear duct length and larger cochlear volume showing the most consistent associations with favorable outcomes. However, the certainty of evidence was very low, precluding firm conclusions regarding the predictive value of anatomical factors.
Abstract
OBJECTIVE: To evaluate the association between cochlear anatomical parameters and postoperative hearing preservation (HP) following cochlear implantation in adults with preoperative residual hearing (RH). METHODS: This systematic review followed PRISMA guidelines (PROSPERO: CRD420250630915). Embase, MEDLINE, PubMed, Scopus, and Web of Science were searched for studies published between 2010 and 2026. Eligible studies included adults (≥ 18 years) with preoperative RH undergoing cochlear implantation, assessed cochlear anatomy using computed tomography or magnetic resonance imaging, reported HP within 6 months postoperatively, and examined the relationship between cochlear anatomy parameter(s) and HP. Risk of bias was evaluated using the QUIPS tool. Data were synthesized narratively; where possible, a meta-analysis using a random-effects model was performed. Certainty of evidence was assessed using GRADE. RESULTS: Ten studies (487 implants) were included. Risk of bias was highest for study participation and confounding. Longer cochlear duct length and larger cochlear volume were suggested to be associated with better HP, though findings were inconsistent. Six studies examined angular insertion depth; four were pooled. Meta-analysis indicated a small positive correlation (pooled r = 0.23; p = 0.004; 95% confidence interval: -0.14 to 0.54), suggesting poorer HP with deeper insertion, with moderate heterogeneity (I 2 = 48.5%). Certainty of evidence for all outcomes was rated very low. CONCLUSION: Cochlear anatomy may influence hearing preservation following cochlear implantation, with longer cochlear duct length and larger cochlear volume showing the most consistent associations with favorable outcomes. However, the certainty of evidence was very low, precluding firm conclusions regarding the predictive value of anatomical factors. LEVEL OF EVIDENCE: 3.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Influence of Cochlear Microanatomy on Hearing Preservation in Cochlear Implant Recipients.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Key pre-operative CT parameters for cochlear implantation: a focused radiologic review with surgical relevanceNeuroradiology · 2026
- Hearing preservation in 41 cochlear implant recipients with preimplant low-frequency residual hearing.Acta oto-laryngologica · 2026
- Incidence and Risk Factors of Cochlear Implant Complications: A Systematic Review and Meta-Analysis.Audiology research · 2026
- Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2026
- Effectiveness of hearing preservation interventions in cochlear implantation patients: A systematic review and meta-analysis.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026